The effects of a new shape-memory alloy interspinous process device on the distribution of intervertebral disc pressures in vitro 被引量:2

The effects of a new shape-memory alloy interspinous process device on the distribution of intervertebral disc pressures in vitro
下载PDF
导出
摘要 This study was designed to measure the pressure distribution of the intervertebral disc under different degrees of distraction of the interspinous process, because of a suspicion that the degree of distraction of the spinous process may have a close relationship with the disc load share. Six human cadaver lumbar spine L2-L5 segments were loaded in flexion, neutral position, and extension. The L3-L4 disc load was measured at each position using pressure measuring films. Shape-memory interspinous process implants (SMID) with different spacer heights, ranging in size from 10 to 20 mm at 2 mm increments, were used. It was found that a SMID with a spacer height equal to the distance of the interspinous process in the neutral position can share the biomechanical disc load without a significant change of load in the anterior annulus. An interspinous process stabilizing device (IPD) would not be appropriate to use in those cases with serious spinal stenosis because the over-distraction of the interspinous process by the SMID would lead to overloading the anterior annulus which is a recognized cause of disc degeneration. This study was designed to measure the pressure distribution of the intervertebral disc under different degrees of distraction of the interspinous process, because of a suspicion that the degree of distraction of the spinous process may have a close relationship with the disc load share. Six human cadaver lumbar spine L2-L5 segments were loaded in flexion, neutral position, and extension. The L3-L4 disc load was measured at each position using pressure measuring films. Shape-memory interspinous process implants (SMID) with different spacer heights, ranging in size from 10 to 20 mm at 2 mm increments, were used. It was found that a SMID with a spacer height equal to the distance of the interspinous process in the neutral position can share the biomechanical disc load without a significant change of load in the anterior annulus. An interspinous process stabilizing device (IPD) would not be appropriate to use in those cases with serious spinal stenosis because the over-distraction of the interspinous process by the SMID would lead to overloading the anterior annulus which is a recognized cause of disc degeneration.
出处 《The Journal of Biomedical Research》 CAS 2010年第2期115-123,共9页 生物医学研究杂志(英文版)
基金 supported by the Medical Key Technology Development Program,Nanjing Health Bureau (ZKK08010)
关键词 Lumbar spine disc pressure interspinous process device BIOMECHANICS Lumbar spine, disc pressure, interspinous process device, biomechanics
  • 相关文献

参考文献15

  • 1Klaus John Schnake,Michael Putzier,Norbert P. Haas,Frank Kandziora.Mechanical concepts for disc regeneration[J].European Spine Journal.2006(3)
  • 2J. Sénégas.Mechanical supplementation by non-rigid fixation in degenerative intervertebral lumbar segments: the Wallis system[J].European Spine Journal.2002(2)
  • 3S. Caserta,G. La Maida,B. Misaggi,D. Peroni,R. Pietrabissa,M. Raimondi,A. Redaelli.Elastic stabilization alone or combined with rigid fusion in spinal surgery: a biomechanical study and clinical experience based on 82 cases[J].European Spine Journal.2002(2)
  • 4S. S. Chung,Chong Suh Lee,Sang Hyun Kim,Min Wook Chung,Jung Mo Ahn.Effect of low back posture on the morphology of the spinal canal[J].Skeletal Radiology.2000(4)
  • 5N. Boos,J. K. Webb.Pedicle screw fixation in spinal disorders: A European view[J].European Spine Journal.1997(1)
  • 6Wilke HJ,Schmidt H,Werner K,Schmolz W,Drumm J.Biomechanical evaluation of a new total posterior-element replacement system[].SPINE.2006
  • 7Lindsey DP,,Swanson KE,Fuchs P,Hsu KY,Zucherman JF,Yerby SA.The Effects of an Interspinous Implant onthe Kinematics of the Instrumented and Adjacent Levels in the Lumbar Spine Derek P[].SPINE.2003
  • 8Swanson K E,Lindsey D P,Hsu K Y,et al.The effects of an interspinous implant on intervertebral disc pressures[].SPINE.2003
  • 9Arnoldi CC,Brodsky AE,Cauchoix J,et al.Lumbar spinal stenosis and nerve root entrapment syndrome: definition and classification[].Clinical Orthopaedics.1976
  • 10Inufusa A,An HS,Lim TH,et al.Anatomic changes of the spinal canal and intervertebral foramen associated with flexion-extension movement[].SPINE.1996

同被引文献19

引证文献2

二级引证文献8

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部