期刊文献+

氧化锆全瓷修复体抗折强度的影响因素 被引量:5

The factors influencing the flexural strength of zirconia ceramic restorations
下载PDF
导出
摘要 氧化锆材料在口腔修复中具有广阔的应用前景,与CAD/CAM技术结合制作的修复体,应用日趋广泛。本文综合了目前常用的氧化锆全瓷修复体的材料特性、抗折性能的影响因素,以及评价其抗折性能的相关指标和方法,为氧化锆全瓷修复的临床应用提供参考。 Zirconia material has a very broad application prospect in prosthodontics,and restorations made of zirconia through CAD/CAM technology have been applied widely in recent years.In this paper we summarized the features of zirconia material which used for all ceramic restorations and the factors which affected its flexural property.We also sated the relevant indicators and methods used for evaluation of flexural property of zirconia material in order to lay a basis for its clinical use.
出处 《上海口腔医学》 CAS CSCD 2010年第5期553-557,共5页 Shanghai Journal of Stomatology
基金 山东大学跨学科科研基金资助项目(53182043)~~
关键词 氧化锆 抗折强度 全瓷冠 Zirconia; Flexural strength; All ceramic crown
  • 相关文献

参考文献29

二级参考文献243

共引文献270

同被引文献55

  • 1介艳巧,张修银.牙科全瓷材料的裂纹扩展模式和影响因素[J].口腔颌面修复学杂志,2010,11(6):358-360. 被引量:1
  • 2宋蓉,王关,李颖,张爽,李天侠.六种黏结剂黏固的铸造嵌体边缘的微渗漏研究[J].牙体牙髓牙周病学杂志,2006,16(5):282-284. 被引量:12
  • 3孙强,何天鹏,韩东,张芳.非均匀的粘结剂层的厚度对全瓷冠应力分布的影响[J].口腔颌面修复学杂志,2006,7(3):181-184. 被引量:13
  • 4Biscaro L, Bonfiglioli R, Soattin M, et al. An in vivo evalu- ation of fit of zirconium-oxide based ceramic single crowns, generated with two CAD/CAM systems, in comparison to metal ceramic single crowns[J]. J Prosthodont, 2013, 22(1): 36-41.
  • 5Cho SH, Nagy WW, Goodman JT, et al. The effect of mul- tiple firings on the marginal integrity of pressable ceramic singlecrowns[J]. J Prosthet Dent, 2012, 107(1): 17-23.
  • 6Eu6n R, Figueras-Alvarez O, Cabratosa-Termes J, et al. Comparison of the marginal adaptation of zirconium dioxide crowns in preparations with two different finish lines[J]. J Prosthodont, 2012, 21(4): 291-295.
  • 7Olivera AB, Saito T. The effect of die spacer on retention and fitting of complete cast crowns[J]. J Prosthodont, 2006,15(4): 243-249.
  • 8Ayad MF. Effects of tooth preparation burs and luting ce- ment types on the marginal fit of extracoronalrestorations[J], JProsthodont, 2009, 18(2).. 145-151.
  • 9Syrek A, Reich G, Ranffl D, et al. Clinical evaluation of all-ceramic crowns fabricated from intraoral digital impres- sions based on the principle of active wavefrontsampling[]]. J Dent, 2010, 38(7).- 553-559.
  • 10MA Cruz, JA Sorenson, WK Johnson. Effect of Venting and Seating Techniques on the Cementation'of Complete Cover- age Restorations [J]. Operative Dentistry, 2008, 33 (6): 690-695.