摘要 火灾条件下影响安全疏散的因素包括隧道中烟气流动性及其温度随时空的分布。针对一端封闭的隧道火灾情形,采用临界温度与临界视距判据,对一端封闭的长300 m掘进中的隧道进行了数值模拟,获得了温度与烟气浓度分布随时空的变化规律,发现其温升速率沿隧道纵向按指数规律衰减,而且临界温度与临界视距交错出现。 In this paper, we have proposed a numerical simulation method for the fire smoking torrent in a tunnel with its one end dead under construction about 300 m long. The purpose of the simulation is to emulate the way of evacuation in case of a tunnel fire in accordance with the criteria of the critical temperature and critical visibility. The real problem here is to find the regularity of temperature distribution and smoke density or the extinction coefficient in regard to the space and time as the reference parameters. The factors to be chosen for safety evacuation mainly include the smoke behavior and the tempera- ture distribution in term of space and time in the tunnel in case of get- ting fire. That is to say, the temperature rising rate (TRR) would de- cay exponentially along with the longitudinal direction of the tunnel whereas the critical temperature and critical visibility inside is chang- ing alternatively, that is to say, at the location of about 120 m from the closed-end in the tunnel fire, the critical temperature is prior to critical visibility but, beyond the location, critical visibility is prior to critical temperature. So the Available Safety Egress Time (ASET) mainly relates with the critical temperature and the critical visibility in the tunnel fire, that is to say, beyond the location of about 120 m, the required time for the critical temperature should be taken into account whereas the required time for the critical visibility accounts beyond the location. These results arc of key significance for the practical personnel evacuation in the on-fire tunnel.
出处 《安全与环境学报》 CAS CSCD 北大核心 2010年第5期156-159,共4页 Journal of Safety and Environment
基金 国家自然科学基金项目(90924014)
关键词 安全工程 隧道火灾 数值模拟 安全疏散 临界温度 临界视距 safety engineering tunnel fire numerical simulation safety evacuation critical temperature critical visibility
  • 相关文献

参考文献18

  • 1马红章,李永红.北天山长大隧道8km独头掘进通风技术[J].铁道建筑技术,2009(5):119-122. 被引量:6
  • 2BRIAN J M.Integrating human factors issues into engineered fire safety design[J].Fire Materials,1999,23:273-279.
  • 3WIECZOREK C J,DEMBSEY N A.Engineering guide for predicting 1st and 2nd degree skin burns[M].Bethesda:SFPE Engineering Task Group on Engineering Practices,1997.
  • 4Los Angeles (California) Fire Department.Operation school burning[M].Boston:National Fire Protection Association,1959.
  • 5POWELL P.Learning fire and life safety fundamentals[M].2nd ed.Stillwater:Oklahoma State University Press,1997.
  • 6HARTZELL G E.Combustion products and their effects on life safety[M].17th ed.Massachusetts:National Fire Protection Association,1991.
  • 7JIN T.Visibility and human behavior in fire smoke[M].3rd ed.Bethesda:Fire Protection Engineering Association,1997.
  • 8JIN T.Visibility through fire smoke[J].Journal of Fire & Flammability,1978,9:135-157.
  • 9JIN T,YAMADA T.Irritating effects of fire smoke on visibility .Fire Science & Technology,1985,5(1):79-89.
  • 10JIN T.Studies of emotional instability in smoke from fires[J].Journal of Fire & Flammability,1981,12:130-142.

二级参考文献4

共引文献5

同被引文献34

  • 1洪丽娟,刘传聚.隧道火灾研究现状综述[J].地下空间与工程学报,2005,1(1):149-155. 被引量:85
  • 2王新钢,毛朝军,叶诗茂,张正卿.浅谈公路隧道火灾及其结构防火保护措施[J].消防技术与产品信息,2005,18(3):65-67. 被引量:20
  • 3喻波,杨高尚,彭立敏,张进华.隧道火灾时人员安全疏散的模拟研究[J].中南公路工程,2006,31(1):158-162. 被引量:8
  • 4陈俊敏,郑雪松,付永胜.性能化防火设计中火灾场景设计的内容和方法[J].西南交通大学学报,2006,41(4):438-441. 被引量:12
  • 5JTG D70-2004.公路隧道设计规范[S]..2004
  • 6Leitner A.The fire catastrophe in the Tauern Tunnel:experience and conclusions for the Austrian guidelines[].Tunnelling and Underground Space Technology.2001
  • 7Hu L H,Li Y Z,Huo R,Yi L,Chow W K.Full-scale experimental studies on mechanical smoke exhaust efficiency in an underground corridor[].Building and Environment.2006
  • 8Meacham Brian. Integrating human factors issues into engineered fire safety design [J]. Fire Mater. , 1999,23 : 273-- 279.
  • 9Jin T. Visibility through fire smoke[J]. J. of Fire Flammabili- ty, 1978,(9):135--157.
  • 10Jin T. Studies on decrease of thinking power and memory in fire smoke[M]. Bull. of Japanese Assoc. of Fire Science Eng. , 1982:43--47.