期刊文献+

家用水冷空调器与风冷空调器运行性能比较 被引量:3

Performance Comparison of Air-cooled and Water-cooled Air-conditioners Applied in Residential Buildings
下载PDF
导出
摘要 本文旨在探讨水冷空调器在住宅中使用的节能潜力。设计了分体式风冷和水冷空调器性能的测试实验台,实验研究在不同的室内负荷和室外干球温度、相对湿度条件下,水冷空调器与风冷空调器的性能和节能效果比较。 The objectives of this study are to evaluate the water-cooled technology for residential cooling applications. A split air-cooled air-conditioner and a prototype water-cooled air-conditioner were set up for experimental test at different indoor and outdoor conditions. The units’performance and power consumption were calculated as baselines for comparison.
出处 《建筑热能通风空调》 2010年第5期11-15,共5页 Building Energy & Environment
基金 天津市自然科学基金(No.08JCYBJC26800)
关键词 热工学 家用空调器 实验研究 性能比较 pyrology domestic air conditioners experimental test performance comparison
  • 相关文献

参考文献8

  • 1王俊,徐伟,林海燕,曾捷.建筑能耗现状与节能途径[J].中国科技成果,2006(19):14-17. 被引量:15
  • 2R Yao,B Z Li,K Steemers.Energy policy and standards for built environment in China[J].Renewable Energy,2005,30:1973-1988.
  • 3Yik FWH,Bornett J,Prescott L Predicting air-conditioning energy consumption of a group of buildings using different heat rejection methods[J].Energy and Buildings,2001,33(2):151-166.
  • 4Yik FWH,Burnett J,Prescott I.A study on the energy performance of three schemes for widening application of water-cooled air-conditioning systems in Hong Kong[J].Energy and Buildings,2001,33(2):167-182.
  • 5John G.Edwards.Water-cooled air-conditioner could be a hit in Las Vegas[J].Review Journal,2002.http://www.reviewjournal.com/lvrj_home/2002/Apr-11-Thu-2002/busi ness/18487495.html.
  • 6Technibel.Single packaged room air-conditioner with water-cooled condenser(1011180-GB-07)[Z].Tré voux CEDEX France.June 2002.
  • 7Yik FWH,Wan KSY,Burnett J.Assessment of envelope energy performance in HK-BEAM for residential buildings[J].The Hong Kong Institution of Engineers Transactions,2000,7(2):49-55.
  • 8Holman J P.Experimental methods for engineers(5th Edition)[M].New York:McGraw-Hill,1989.

共引文献14

同被引文献15

  • 1程新燕.电力变压器热性故障分析[J].新疆电力技术,2010(4):50-51. 被引量:4
  • 2Yik FWH, Burnett J,Prescott I. Predicting air-conditioning energy constmaption of a group of buildings using different heat rejection methods [J]. Energy and Buildings, 2001, 33(2): 151-166.
  • 3Yik FWH, Burnett J, PrescottI.A study on the energy performance of three schemes for widening application of water-cooled airconditioning systems in Hong Kong [J]. Energy and Buildings, 2001, 33(2): 167-182.
  • 4S S Hu, B J Huang. Study ofahigh efficiency residential split water-cooled air conditioner [J]. Applied Thermal Engineering, 2005, 25(11-12): 1599-1613.
  • 5W L Lee, Hua Chen, F W H Yik. Modeling the performance characteristics of water-cooled air-conditioners [J]. Energy and Buildings, 2008, 40(8): 456-1465.
  • 6Hua Chen, W L Lee, F W H Yik. Applying water cooled air condi -tioners in residential buildings in Hong Kong [J]. Energy Conversion and Management, 2008, 49(6): 1416-1423.
  • 7弗兰克P瑛克鲁佩勒,大卫P.德维特.传热和传质基本原理[M].葛新石,叶宏,译.6版,北京:化学工业出版社,2009.
  • 8刘中杰,刘利娜.窗机室外侧风机风道系统CFD优化[J].价值工程,2010,29(15):197-197. 被引量:1
  • 9卜春贵.暧通空调节能技术探析[J].中国科技纵横,2010(23):222-222. 被引量:2
  • 10姬利明,祁影霞,欧阳新萍.制冷剂气体水合物用于蓄冷空调中的探讨[J].低温与超导,2010,38(11):58-62. 被引量:3