摘要 上海由于地处长江流域,冬季相对湿度较高,建筑围护结构内部结露的风险较大。本文通过定常计算得出当保温材料及隔湿材料贴附时,抑制墙体内部结露的效果,并提出了调湿材料在该类型地区应用的不同方式。 Shanghai is located in the Yangtze River, so the relative humidity is high in winter. The condensation risk is relatively high in the envelope. Through the stationary calculation when the thermal insulation material and separated wet material is attached, this paper achieves the inhibitory effect of condensation within the wall. It also suggests a few application methods of desiccant material in high humidity area.
出处 《建筑热能通风空调》 2010年第5期55-58,共4页 Building Energy & Environment
关键词 被动调湿 高湿地区 保温隔湿 调湿材料 passive controlling of humidity high humidity area insulation and separation of humidity humidity-controlling material