期刊文献+

植入式柔性神经微电极的互连方法

An electrical interconnect method for implantable flexible neural microelectrodes
原文传递
导出
摘要 为了实现植入式柔性神经微电极与外部记录或刺激装置的有效、可靠连接,本文提出了一种基于通孔电镀的植入式柔性神经微电极互连方法。该方法首先制作具有通孔结构的柔性互连膜,并将其通孔与待连接的植入式微电极焊接位点对准贴合,然后电镀生长导通金属,从而实现与待连接的植入式器件的柔性连接。最后本文通过SEM观察、电学性能测试、机械强度测试以及生物兼容性测试等手段对此互连方法的焊接效果进行了评价。测试结果表明本文提出的柔性微电极互连方法具有很好的可靠性和稳定性。 In order to achieve efficient and reliable interconnection between implantable flexible neural microelectrodes and external stimulation and record devices,an electrical interconnect method based on via-hole electroplating has been presented in this paper.In this method,a flexible interconnect film including via-hole structures was first fabricated,and then bonded on a flexible neural microelectrode after aligning its via-holes with the welding pads of the flexible neural microelectrode.After that,an electroplating process was performed to fill the via-holes with the growth of metal,which could form an electrical connection between the flexible interconnect film and the flexible microelectrode.Finally,the fabricated devices were investigated by SEM,electrical performance test,mechanical strength test,and biocompatibility test.The results show that the proposed interconnection method for the flexible microelectrodes has good reliability and stability.
出处 《功能材料与器件学报》 CAS CSCD 北大核心 2010年第5期471-478,共8页 Journal of Functional Materials and Devices
基金 国家973计划(No.2005CB724305) 上海市自然科学基金项目(No.07ZR14134) 上海市AM基金项目(No.08520740300) 中国科学院上海微系统与信息技术研究所青年创新基金项目(No.2008QNCX02)
关键词 柔性基底 神经微电极 电镀 互连 Flexible substrate Neural Microelectrode Electroplating Interconnection
  • 相关文献

参考文献19

  • 1Ulbert I, Halgren E, Heit G, Karmos G. Multiple microelectrode- recording system for human intracortical applications. Journal of neuroscience methods, 2001, 106 ( 1 ) : 69 - 79.
  • 2Heer F, Hafizovic S, Ugniwenko T, Frey U, Franks W, Perriard E, Perriard J, Blau A, Ziegler C, Hierlemann A. Single-chip microelectronic system to interface with living ceils. Biosensors and Bioelectronics, 2007, 22 ( 11 ) :2546 - 2553.
  • 3Sheffler L, Chae J. Neuromuscular electrical stimulation in neurorehabilitation. Muscle and Nerve, 2007, 35 (5) :562 - 590.
  • 4Peckham P, Knutson J. Functional electrical stimulation for neuromuscular applications. Annual review of biomedical engineering, 2005, 7:327 - 360.
  • 5Merrill E, Ainsworth A. Glass -coated platinum -plated tungsten microelectrodes. Medical and Biological Engineering and Computing, 1972, 10(5) :662 - 672.
  • 6Schanne O, Lavallee M, Laprade R, Gagne S. Electrical properties of glass microelectrodes. Proceedings of the IEEE, 1968, 56(6) :1072 - 1082.
  • 7Limousin P, Krack P, Pollak P, Benazzouz A, Ardouin C, Hoffmann D, Benabid A. Electrical stimulation of the subthalamic nucleus in advanced Parkinson 's disease. New England Journal of Medicine, 1998, 339 (16) : 1105- 1111.
  • 8Serruya M, Hatsopoulos N, Paninski L, Fellows M, Donoghue J. Brain - machine interface : Instant neural control of a movement signal. Nature, 2002, 416 ( 6877 ) : 141 - 142.
  • 9Benabid A, Pollak P, Gao D, Hoffmann D, Limousin P, Gay E, Payen I, Benazzouz A. Chronic electrical stimulation of the ventralis intermedius nucleus of the thalamus as a treatment of movement disorders. Journal of neurosurgery, 1996, 84(2):203 -214.
  • 10Loeb G. Cochlear prosthetics. Annual Review of Neuroscience, 1990, 13(1):357-371.

二级参考文献25

  • 1[1]HOAG H.Remote control[J].Nature,2003,423(6942):796-798.
  • 2[2]MAYNARD E M,NORDHAUSEN C T,NORMANN R A.The utah intracortical electrode array:a recording structure for potential brain-computer interfaces[J].Electroencephalogr Clin Neurophysiol,1997,102(3):228-
  • 3[3]STIEGLITZ T,MEYER J U.Implantable microsystems:Polyimide-based neuroprostheses for interfacing nerves[J].Med.Device Technol.,1999,10(6):28-30.
  • 4[4]LIMOUSIN P,KRACK P,POLLAK P,et al..Electrical stimulation of the subthalamic nucleus in advanced Par-kinson's disease[J].N Engl J Med,1998,339(16):1105-1111.
  • 5[5]SERRUYA M D,HATSOPOULOS N G,PANINSKI L,et al..Instant neural control of a movement signal[J].Nature,2002,416(6877):141-142.
  • 6[6]HOUSE W.Cochlear implants:from the idea to clinical practice[J].Language,1993:9-33.
  • 7[7]MARGALIT E,MAIA M,WEILAND J D,et al..Retinal prosthesis for the blind[J].SurvOphthalmol,2002,47(4):335-356.
  • 8[8]KOVACS G T,STORMENT C W,HALKS-MILLER M,et al..Silicon-substrate microelectrode arrays for parallel recording of neural activity in peripheral and cranial nerves[J].IEEE Trans Biomed Eng,1994,41(6):567-577.
  • 9[9]HETKE J F,WILLIAMS J C,PELLINEN D S,et al..3-D silicon probe array with hybrid polymer interconnect for chronic cortical recording[C].Neural Engineering,2003.Conference Proceedings.1st International IEEE EMBS Conference on,2003:181-184.
  • 10[10]KIPKE D R.Implantable neural probe systems for cortical neuroprostheses[C].26th Annual International Conference,2004:5344-5347.

共引文献11

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部