期刊文献+

轻型木结构剪力墙抗侧力性能试验与有限元分析 被引量:16

Testing and FE modeling of lateral resistance of shearwalls in light wood frame structures
下载PDF
导出
摘要 为研究国产钉连接轻型木结构剪力墙的抗侧力性能,对7组14片不同尺寸规格和构造的剪力墙进行了标准推力试验,并利用ABAQUS建立了剪力墙的有限元模型,对其工作性能进行分析.结果表明:钉连接失效是导致剪力墙破坏的主要原因;剪力墙的承载力和刚度与墙体宽度成正比;开洞剪力墙的承载性能均比宽度与洞口两侧墙肢总宽度相等的剪力墙高;石膏板对剪力墙的承载性能有显著提高作用.由试验和有限元分析结果拟合得到了预测剪力墙的荷载-位移曲线、极限承载力和刚度的经验公式. In order to investigate the performance of shearwalls connected with domestic nails in light wood frame structures, lateral resistance tests were conducted on 14 shearwalls in 7 groups with different dimensions and structural arrangements. Using ABAQUS, FE models of shearwalls were developed to simulate the structural behaviour, Both the experimental and numerical results show that failure of nail connections is the primary cause leading to the failure of shearwalls. The load-carrying capacity and the stiffness of shearwalls are pro- portional to the width. The performance of shearwalls with an opening, in terms of load-carrying capacity and stiffness, is higher than that of shearwalls without an opening but with the width equaling to the sum of the wall segments from the two sides of the opening. Gypsum panels improve the performance of shearwalls significantly. The empirical equations to predict the lateral resistance and stiffness of shearwalls were derived based on the test and FE modelling.
出处 《哈尔滨工业大学学报》 EI CAS CSCD 北大核心 2010年第10期1548-1554,共7页 Journal of Harbin Institute of Technology
基金 哈工大海外留学人员回国工作科研启动项目
关键词 轻型木结构 剪力墙 抗侧力试验 有限元 light wood frame structure shearwall lateral resistance testing finite element
  • 相关文献

参考文献2

二级参考文献11

  • 1中华人民共和国建设部.GB50005-2003木结构设计规范[S].北京:中国建筑工业出版社,2005.
  • 2prEN 1995 - 1 - 1 : 2003. Euroeode 5 : Design of timber structurespart 1 :General rules and rules for buildings [S]. European Committee for Standardiza-tion, Brussels, 2003.
  • 3ASTM. Standard test methods for mechanical fasteners in wood. Designation D1761 [ S]. America Society of Testing and Materials, West Conshohocken, PA, 1988.
  • 4European standard. EN 26891. Timber structures - Joints made with mechanical fasteners - general principles for the determination of strength and deformation characteristics [ S]. European Committee for Standardization, Brussels, 2001.
  • 5GIRHAMMAR Ulf Ame , BOVIRN Nils Ivar. Characteristics of sheathing - to - timber joints in wood shear walls [ C]. WCTE 2000 6th World Conference on Timber Engineering, 2000.
  • 6NAKAJIMA S, OKATE M. Effects of dry and humid cyclic climate on the performance of nail joints and shear walls[ C]. WCTE 2004 8th World Conference on Timber Engineering, 2004, Volume I : 117-122.
  • 7Step( 1995 ) Timber Engineering, Step, Volumes 1 and 2 [ M]. Centrum Hout, Netherlands, 1995.
  • 8DONALT E Breyer. Design of wood structures - ASD [M]. 5th ed. McGraw - Hill, 2004.
  • 9CSA (1994) CAN/CSA - 086.1 - 94, Engineering Design in Wood (Limit States Design) [ S]. Canadian Standards Association, Ottawa, 1994.
  • 10DOLAN J D, MADSEN B . Monotonic and cyclic nail connection tests [ J ]. Canadian Journal of Civil Engineering. Ottawa, Canada, 1997,19 ( 1 ) : 104.