摘要 随着系统频率的提高,衬底材料特性已成为影响信号走线之间串扰的一个不可忽略的因素。该文基于传输线方程和频域S参数对两平行微带线间串扰耦合进行理论分析,并结合全波3维电磁场仿真工具对具有不同介电常数和不同厚度的衬底材料进行了仿真和分析,得到了微带线在不同衬底下的电场分布,以及近端和远端串扰随频率、衬底介电常数和厚度变化的曲线。随着频率的增大,远端串扰将大于近端串扰,并且随着衬底介电常数和厚度的增加,微带线间的串扰呈现正弦上升的变化趋势。 With the increasing of system frequency,the characteristics of microstrip substrates are non-ignorable factor for affecting the crosstalk between transmission lines.This paper analyzes the crosstalk between two parallel microstrip lines based on the transmission line equations and S parameters,simulates the crosstalk with different permittivity and thickness of the substrate with 3D full-wave electromagnetic tool.The electric field distributions of microstrips with different substrates and the results of near-end and far-end crosstalks with the changing of frequency,substrate permittivity and thickness are obtained.The far-end crosstalk will be greater than the near-end crosstalk with the frequency increasing,and moreover,with the increasing of substrate permittivity and thickness,the crosstalks of microstrips will present a sine upward trend.
作者 白雪 徐雷钧
出处 《电子与信息学报》 EI CSCD 北大核心 2010年第11期2768-2771,共4页 Journal of Electronics & Information Technology
基金 江苏省高校自然科学研究项目(10KJB510002)资助课题
关键词 微带线 串扰 衬底 介电常数 Microstrip Crosstalk Substrate Permittivity
  • 相关文献

参考文献11

  • 1Ciamulski T and Gwarek W K. Coupling compensation concept applied to crosstalk cancelling in multiconductor transmission lines [J]. IEEE Transactions on Electromagnetic Compatibility, 2008, 50(2): 437-441.
  • 2Broyde F and Clavelier E. A new method for the reduction of crosstalk and echo in multiconductor interconnections [J]. IEEE Transactions on Circuits and Systems I: Regular Papers 2005, 52(2): 405-416.
  • 3Ciamulski T and Gwarek W K. On eliminating crosstalk within multiconductor transmission lines [J]. IEEE Microwave and Wireless Components Letters, 2004, 14(6): 298-300.
  • 4Ding Wei-qiang, Tang Dong-hua, and Liu Yan, et al.. Compact and low crosstalk waveguide crossing using impedance matched metamaterial [J]. Applied Physics Letters 2010, 96(11): 1-3.
  • 5朱樟明,钱利波,杨银堂.一种基于纳米级CMOS工艺的互连线串扰RLC解析模型[J].物理学报,2009,58(4):2631-2636. 被引量:9
  • 6李鑫,Janet M.Wang,张瑛,唐卫清,吴慧中.工艺随机扰动下非均匀RLC互连线串扰的谱域方法分析[J].电子学报,2009,37(2):398-403. 被引量:4
  • 7董刚,李跃进,杨银堂.两相邻耦合RLC互连的串扰估计[J].电路与系统学报,2006,11(2):149-152. 被引量:2
  • 8Song E, Cho J, and Kim J, et al.. Modeling and design optimization of a wideband passive equalizer on PCB based on near-end crosstalk and reflections for high-speed serial data transmission [J]. IEEE Transactions on Electromagnetic Compatibility, 2010, 52(2): 410-420.
  • 9黎淑兰,刘元安,唐碧华.降低有损耦合微带线间串扰的方法分析[J].电波科学学报,2006,21(4):503-507. 被引量:6
  • 10Yang Yi, Liu Yi-fang, and Zhou Ya-ping, et al.. Minimizing crosstalk in high-speed differential buses by optimizing power/ground and signal assignment [C]. IEEE 18th Conference on Electrical Performance of Electronic Packaging and Systems, Portland, OR, USA, Oct. 19-21, 2009: 255-258.

二级参考文献40

共引文献16

同被引文献24

  • 1李丽平,李玉山,王崇剑.防护线减小微带线间串扰的FDTD分析[J].电子与信息学报,2006,28(3):574-576. 被引量:16
  • 2黎淑兰,刘元安,宋占海,兰芳.耦合微带线间串扰问题的FDTD法分析[J].微波学报,2006,22(2):17-20. 被引量:7
  • 3齐磊,崔翔.变电站开关操作对屏蔽电缆电磁干扰的预测[J].中国电机工程学报,2007,27(9):46-51. 被引量:34
  • 4Anon. Proceedings of the seventh WVU mining electrotechnology conference[C]//Proceedings of the Seventh WVU Mining Electrotechnology Conference,Morgantown,West Virginia,America,1984.
  • 5Fernandes D J, Neves W L A, Vasconcelos J C A. Coupling capacitor voltage transformer: A model for electromagnetic transi- ent studies[J]. Electric Power Systems Research, 2007,77 (2) : 125-134.
  • 6Kenneth L K, Karen I P. Cable transient voltages due to microphonics[J]. Journal of Electrostatics, 2007,65 (12):723-727.
  • 7Marzinotto M, Mazzetti C. Overvoltage attenuation in power cable lines-A simplified estimation method[J]. Electric Power Systems Research,2010, 80(5) :506-513.
  • 8DeMedeiros L H A,Rosas P A C, Lins Z D, et al. High frequency transients and electromagnetic interference within 69 kV [J]. Electric Power Systems Research,2011,81(7) : 1534-1540.
  • 9Popov M,Sluis L,Smeets R P P. Evaluation of surgetransferred overvoltages in distribution transformers[J]. Electric Power Systems Research,2008,78(3) :441 -449.
  • 10RAUSCHMAYER D J. ADSL/VDSL Principles[M]. Indiana: Macmillan Technical Publishing, 1999.

引证文献3

二级引证文献9

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部