期刊文献+

压缩制冷复合循环间冷机组热经济性分析与虚拟计算 被引量:2

Analysis and Fictitious Computation on Thermal Economic Performance of Compressed Refrigerating Cycle for Air Cooling Steam Turbine Unit
下载PDF
导出
摘要 简要回顾以氨气压缩制冷为复合循环间接空气冷却系统的正循环系统(简称"压缩制冷复合循环间冷系统")的构建及工作原理。基于热力学原理拟订了制冷循环热经济性能评价方法和评价指标;以蒙东某地亚临界600 MW直冷机组为比较基准,进行了同环境、同容量、同型号但不同低压缸的虚拟压缩制冷复合循环间冷机组的热经济性能评价指标的虚拟计算。从理论上导出了制冷循环年累计产/耗电量比大于1的存在必要条件为转捩温度Tt必须高于正/逆制冷循环切换温度Ts,且高得越多,热经济性能越佳;揭示了转捩温度的数值大小与产能和耗能设备的效率密切相关,切换温度与汽轮机排气背压及机组安装地的气象条件有关。 The components and process flow diagram of the positive sequence refrigerating of compound cycle air cooling unit(CCACU) was reviewed briefly(henceforth called 'compressed refrigerating CCACU').Based on the law of conservation of energy,the thermal economy of compressed refrigerating cycle for high temperature duration was drawn up,the basic economic evaluations were worked out.By taking a subcritical 600 MW unit with DAC(Direct air cooling) system(DAC unit for short) in eastern Inner Mongolia as a benchmark,a CCACU(fictitious unit in brief) which is in possession of the same environment was fabricated,same capacity and same model but different low pressure casing structure with the DAC unit and performed the fictitious computation of economic evaluations for it.The conclusions are that the production/ consumption energy ratio may be greater than 1 even in high temperature duration,the necessary condition for achieving this object is that Tt Ts and the higher the better;secondly,the numerical value of Tt is closely related to the efficiency of energy-producing energy-consuming equipments,but Ts is related to the turbine exhaust back pressure and the weather data of plant site.
出处 《中国电机工程学报》 EI CSCD 北大核心 2010年第32期13-19,共7页 Proceedings of the CSEE
基金 国家重点基础研究发展计划项目(973计划)(2007CB206904) 中国华能集团公司科学技术项目(HNKJ08-H32)~~
关键词 复合循环间冷机组 热经济性评价指标 切换温度 转捩温度 虚拟计算 compound cycle air cooling unit(CCACU) thermal economic evaluation switching temperature transition temperature fictitious computation
  • 相关文献

参考文献3

二级参考文献32

共引文献21

同被引文献29

  • 1丁国良.制冷空调装置的计算机仿真技术[J].科学通报,2006,51(9):998-1010. 被引量:31
  • 2樊泉桂.提高超临界和超超临界机组发电效率的关键技术[J].电力设备,2006,7(7):30-34. 被引量:12
  • 3周兰欣,杨靖,杨祥良.300MW直接空冷机组变工况特性[J].中国电机工程学报,2007,27(17):78-82. 被引量:69
  • 4曾丹苓,敖越,张新铭,等.工程热力学[M].3版.北京:高等教育出版社,2004:30.
  • 5沈维道,童钧耕.工程热力学[M].4版.北京:高等教育出版社,2007.
  • 6LIU Li-hua,DU Xiao-ze,XI Xin-ming,et al.Experimental analysis of parameter influences on the performances of direct air cooled power generating unit[J].Energy,2013,56: 117-123.
  • 7DU Xiao-ze,Hu He-min,Shen Yin-qi,et al.Reduced order analysis of flow and heat transfer for air-cooled condenser of power generating unit[J].Applied Thermal Engineering, 2013,51: 383-392.
  • 8ALLEMANN R T,DEBELLIS D E,WERRY E V,et al.Wet-dry cooling demonstration: test results [R]. Richland, USA: Pacific Northwest Laboratories, 1986.
  • 9MILLIARAS E S.Power plants with air-cooled condensing systems [M].Cambridge: The MIT Press, 1974.
  • 10MCHALE C E,JABLONKA G E,BARTA J A,et al.A new developments in dry cooling of power plants [J].Combustion,1980,51(11): 28-36.

引证文献2

二级引证文献5

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部