微波加热阻断分解后测定冻水产品中多聚磷酸盐-离子色谱法 被引量:1

Determination of polyphosphates in frozen seafood-Ion chromatography after microwave heating
原文传递
导出
摘要 目的:比较讨论了不同微波加热温度,不同蛋白沉淀剂对加标回收率的影响。方法:建立了一种采用去离子水提取,微波加热阻断分解,三氯甲烷作为蛋白沉淀剂对冻水产品进行前处理,过Ag柱、H柱净化,再用KOH进行梯度淋洗,抑制型电导离子色谱法检测冻水产品中多聚磷酸盐的方法。结果:使用三氯甲烷前处理具备抗污染能力强,灵敏度高等特点,最终样品检测结果令人满意。结论:95℃热处理10 min阻断聚磷酸钠分解,加三氯甲烷沉淀蛋白,KOH梯度淋洗,AS11柱分离,可检测冻水产品中的焦磷酸钠、三聚磷酸钠和三偏磷酸钠。 Objective: To find the effects of different microwave heating temperature and protein precipitation agents on recoveries.Methods: We established a method in which extract polyphosphates from seafood products by deionized water.The decomposition was blocken after we using microwave heating.The chloroform was used as a protein precipitating.We use the Ag column,H column,and analyse polyphosphates by conductivity ion chromatography whose gradient eluents were obtained by Eluent Generator.Results:Using chloroform pre-treatment method is resistant to pollution,high sensitivity.Conclusion: The final sample test results were satisfactory.
出处 《中国卫生检验杂志》 CAS 2010年第11期2766-2768,共3页 Chinese Journal of Health Laboratory Technology
关键词 离子色谱 三氯甲烷 冻虾仁 多聚磷酸盐 微波加热 Conductivity ion chromatography Chloroform Frozen shelled fresh shrimps Polyphosphates Microwave heating
  • 相关文献

参考文献8

二级参考文献25

共引文献255

同被引文献13

引证文献1