摘要
目的:比较RT-PCR和Real time PCR检测甲型H1N1流感病毒的灵敏度。方法:体外转录生成甲型H1N1流感病毒M基因235 bp的保守序列作为阳性毒株RNA为模板,计算出相应的拷贝数后进行10倍梯度稀释,在引物探针的作用下分别进行RT-PCR和Real time PCR的检测。结果:Real time PCR的最低检测限为8 copies/μl,RT-PCR的最低检测限为80 copies/μl,线性关系好。结论:检测甲型H1N1流感病毒Real time PCR方法比RT-PCR灵敏度高10倍。
Objective:To compare the sensitivity for detection H1N1 influenza virus by RT-pcr and real-time pcr.Methods: Conserved Sequence of 235bp was transcribed in H1N1 influenza virus as positive control template,the concentration of which was ordinal diluted by 1:10 after the total numbers of copies was obtained.The two methods above were applied to continue detection with the primers and probes.Results: The detection limit of RT-pcr and real-time pcr was 80 copies/μl and 8 copies/μl respectively.Conclution: The sensitivity of real-time pcr method is 10 times higher than RT-pcr method.
出处
《中国卫生检验杂志》
CAS
2010年第11期2823-2824,共2页
Chinese Journal of Health Laboratory Technology