摘要
目的建立对氧磷酶(paraoxonase,PON)活性测定方法,调查正常人及肝病患者(肝癌与肝硬化)血清PON活性。方法PON活性测定用分光光度法,同时检验批内差异、批间差异、重复性、线性关系及回收率。结果正常人血清PON活性平均值为154.3kU/L,参考值范围为82.1~220.6kU/L,肝病患者PON活性平均值为81.1kU/L。结论肝病患者血清PON活性较正常人明显下降,其差别有显著性(P<0.01)。
ObjectiveTo establish a serum paraoxonase(PON) activity assay method and the common reference values of PON activity in human serum.MethodsPON activities were detected by spectrophotography.The same method was used to measure precision between batchs and within batchs, the reproducibility,and to assess the linear correlation and recovery rate.ResultsThe coefficient of variation (CV) between batchs was 3.6 % and CV within batchs was 2.19 %.The average value of serum PON activity was 54.3 ku/L( 82.1 - 220.6 ku/L) in normal human.The enzymatic activity was 81.1 ku/L ( 13.03 - 210.1 ku/L) in the patients with liver cancer and hepatocirrhosis.ConclusionThe method was reliable and reproducible. PON activities reduced significantly in the patients with liver cancer or hepatocirrhosis ( P < 0.01 ).
出处
《河北医科大学学报》
CAS
1999年第3期134-136,共3页
Journal of Hebei Medical University
关键词
对氧磷
代谢
酶试验
肝疾病
paraoxon/metab
enzyme test
liver diseases