摘要
对华能珞璜360MW机组"W"火焰无烟煤锅炉采用双强少油燃烧器进行改造,详述改造方案,改造后进行了稳燃等试验,并对节能效益进行分析,提高了电厂运行的安全性和经济性,达到了节能降耗的目的。
To Huaneng Luohuang 360MW unit "W" flame anthracite-fired boilers, ignition With Little-oil Technology Strengthened in two aspects is used, the retrofit of the program is specified, tests of stable combustion and other tests after the retrofit are carried out, and the efficiency of energy-saving is analyzed, operation safety and economy of power plant is improved, achieved the purpose of energy-saving.
出处
《电站系统工程》
北大核心
2010年第4期25-26,29,共3页
Power System Engineering
关键词
双强少油燃烧器
“W”火焰
无烟煤锅炉
应用
节能
ignition with little-oil technology
‘W' flame
anthracite-fired boiler
application
energy-saving