摘要
国华定洲发电厂一期2×600MW机组汽轮发电机采用双流双环式密封瓦,在历次检修过程中,多次发生密封瓦径向间隙超差情况。主要探讨修复双流双环密封瓦所遇到的问题以及工艺方法。
the dual stream loop seals tile is applied on the 2 ×600MW Unit 1 turbine generator of Guohua Dingzhou Power Plant. In the previous inspections, many occasions, such as a tile radial clearance of an uhra-poor situation had happened, therefore, this paper focus on the investigation of the technology used to solve the problem in the case of the dual stream loop seals.
出处
《神华科技》
2010年第3期62-65,共4页
Shenhua Science and Technology
关键词
双流双环
密封瓦
径向间隙
超标
修复
工艺
Dual steam dual loop
Tile seal
Excessive radial clearance
Over standard
Repair
Technique