摘要 当前城市热网和热源存在诸多问题,例如热网输送能力不足,热源运行达不到设计值,大型调峰热源不能对负荷变化进行频繁及时调整等。针对这些问题可以考虑利用区域型锅炉房作为调峰热源,热电联产作为主要热源并联合供热的方式进行供热。确定了区域型锅炉的调峰负荷,对比了不同调峰系数下的寿命周期费用,计算得出区域型锅炉开启的室外温度。结果表明:利用区域型锅炉房作为调峰热源具有良好的经济优势。 Many problems exist in city heating source and network such as low transmission capacity, inability to reach the expected value for the operation of heat source, impossibility to adjust the load of large peak heat source timely and frequently, etc.. In view of this, medium and small boilers could be considered the peak load regulating heat source and CHP the main heat source to have the combined heating supplies. The peak load of medium and small boilers has been determined, the life cycle costs of different peak shaving coefficients have been compared and the outdoor operation temperature for the medium and small boilers has been worked out. Results show that the new scheme is more economic.
出处 《洛阳理工学院学报(自然科学版)》 2010年第4期13-16,共4页 Journal of Luoyang Institute of Science and Technology:Natural Science Edition
关键词 区域锅炉 二级网 调峰 寿命周期费用 medium and small boilers secondary network~ peak load regulating life cycle cost
  • 相关文献

参考文献4

二级参考文献13

  • 1[1]Jacob Kaminsky.District Heating and Cooling Technology Research and Development Overview of the U.S.Department of Energy Program[J].CFfice of Building and Community,U.S .DOE.
  • 2[3]Faruk Mendi, Kurtulus Boran. Fuzzy controlled central heating system[J]. International Journal of Energy Research, 2002, 26(15)1313~1322.
  • 3中国城市集中供热2000年技术进步发展规划编号组.中国城镇集中供热2000年技术进步发展规划[J].区域供热,1995,(1):1-4.
  • 4[7]C. Filippln. Benchmarking the Energy Efficiency and Greenhouse Gases Emissions of School Buildings in Central Argentina[J]. Building and Environment, 2000,35(5):407~414.
  • 5[8]Kodal A, Sahin B,Yilmaz T. Effects of Irreversibility and Leakage on the Finite Time Thermoeconomic Performance of Refrigerators and Pumps[J].Energy Convers Mgmt,2001,42:607~619.
  • 6[10]Kodal A, Sahin B. Thermoeconomic Optimization for Irreversible Absorption Refrigerators and Heat Pumps[J]. Energy Convers Mgmt, 2003,44:109~123.
  • 7[11]Joanne M. Holford. Gary R. Hunt. Fundamental Atrium Design for Natural Ventilation[J]. Building and Environment, 2003,38(3):409~426.
  • 8张寅平.一种相变蓄热电取暖器.99214838.3.2000-01-14.
  • 9Eric Martinot, Investments to improve the energy efficiency of eti stingresidential buildings in countries of the former soviet union. World Bank Publications. 稿件修回日期:2000-05-16
  • 10秦绪忠,江亿.集中供热网的可及性分析[J].暖通空调,1999,29(1):2-7. 被引量:36

共引文献124

同被引文献5

引证文献1

二级引证文献1

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部