摘要 对管壳式换热器壳程进出口折流区的传热温差作了分析,以换热器热流体与冷流体的出口温度比例α表征换热器的换热深度,探讨了换热器换热深度与长径比的关系。采用流路分析方法,对换热器壳程折流区域的传热性能进行了数学分析,并与纯逆流情况作了对比。结果表明:换热器折流区域的传热温差较逆流区域传热温差的偏离量会随α的改变而产生变化,为避免偏移量过大应控制折流区域面积占总传热面积的比例。α<1时,为使传热温差偏移小于5%应使折流区域面积占总传热面积的比例小于0.6/R1 a,c。揭示了现有换热器结构大型化之后难以实现α<1的原因,并给出一种可以改进传统大型管壳式换热器长径比锐减、换热深度受限的有效结构——壳程多通道结构。 Heat transfer temperature difference deviation analysis for baffle flow area at inlet and outlet in shell side of shell and tube heat exchangers was presented.The ratio of outlet temperature of hot fluid to that of cold one α indicated the degree of heat transfer depth.In order to study the relationship between the ratio of length to diameter and heat transfer depth,the heat transfer performance in baffle flow pattern was mainly compared with that in counter flow pattern in terms of flow distribution analysis.The results show that deviation of heat transfer difference changes as a change of α.And the ratio of baffle flow area to the whole area should be changed for different α in order to control the deviation of heat transfer temperature difference not too much.The ratio of baffle flow area to the whole area of heat exchangers should be smaller than to control deviation of heat transfer temperature difference under 5% when α1.The reasons why traditional large shell and tube heat exchangers can′t achieve α1 were presented.The techniques should be incorporated to further enhance the heat transfer coefficient of heat exchangers and multi-parallel-channel structure in shell side is such an advantageous configuration.
出处 《化学工程》 CAS CSCD 北大核心 2010年第10期73-77,共5页 Chemical Engineering(China)
基金 国家自然科学基金资助项目(20776046)
关键词 换热器 逆流 折流 传热温差损失 流路分析 优化设计 heat exchanger counter flow baffle flow deviation of heat transfer temperature difference flow distribution analysis optimal design
  • 相关文献

参考文献11

  • 1RAJA V A P, BASAK T, DAS S K. Thermal performance of a multi-block heat exchanger designed on the basis of Bejan's constructal theory[ J]. International Journal of Heat and Mass Transfer, 2008, 51 (13/14): 3582-3594.
  • 2ZHANG Jian-fei, LI Bin, HUANG Wen-jiang. Experimental performance comparison of shell-side heat transfer for shell-and-tube heat exchangers with middle-overlapped helical baffles and segmental baffles [ J]. Chemical Engineering Science, 2009,64 ( 8 ) : 1643-1653.
  • 3LI H, KOTTKE V. Analysis of local shellside heat and mass transfer in the shell-and-tube heat exchanger with disc-and-doughnut baffles [ J ]. International Journal of Heat and Mass Transfer, 1999,42 ( 18 ) : 3509-3521.
  • 4WANG Chen, ZHU Jiaqui, SANG Zhifu. Experimental studies on thermal performance and flow resistance of heat exchangers with helical baffles [ J ]. Heat Transfer Engineering, 2009,30(5 ) :353-358.
  • 5PENG B, WANG Q W, ZHANG C. An experimental study of shell-and-tube heat exchangers with continuous helical baffles [ J ]. Journal of Heat Transfer-Transactions of the Asme, 2007,129(10) : 1425-1431.
  • 6WANG Qiuwang, CHEN Qiuyang, CHEN Guidong. Numerical investigation on combined multiple shell-pass shell-and-tube heat exchanger with continuous helical baffles [ J]. International Journal of Heat and Mass Transfer, 2009,52 (5/6) : 1214-1222.
  • 7邓先和,黄维军.急扩加速流缩放管气体换热器的结构及应用[J].硫酸工业,2005(5):22-24. 被引量:14
  • 8王杨君,邓先和,李志武.旋流片支撑缩放管管束的复合强化传热[J].化工学报,2007,58(9):2190-2193. 被引量:8
  • 9王杨君,邓先和,李志武,洪蒙纳.旋流片支撑管束的传热与流阻性能[J].化工学报,2007,58(1):21-26. 被引量:13
  • 10邓先和,蒋夫花.换热器在大型化发展中的深度换热问题讨论[J].硫酸工业,2009(6):1-5. 被引量:7

二级参考文献28

共引文献32

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部