摘要
论述了给水泵汽轮机的可靠性对于机组的实际意义,介绍了国产350MW超临界机组的给水泵配置方案,分析了异常跳闸事故原因,提出了解决方案,供同类型机组调试及运行时借鉴和参考。
The practical significance of the reliability of boiler feed water pump turbine to the unit was expounded.The configuration scheme of the feed pump of domestic 350MW supercritical unit was introduced.The reasons of abnormal tripping accident were analyzed;and resolving scheme was put forward,which can be used as reference for the same units in commission and operation.
出处
《华电技术》
CAS
2010年第11期32-33,共2页
HUADIAN TECHNOLOGY
关键词
超临界机组
给水泵汽轮机
异常跳闸事故
解决方案
可靠性
supercritical unit
boiler feed water pump turbine
abnormal tripping accident
resolving scheme
reliability