OCT不同扫描模式在检测视网膜神经纤维层厚度中的应用 被引量:2

Application of different OCT scanning patterns on detecting retinal nerve fiber layer thickness
下载PDF
导出
摘要 目的比较3种OCT扫描模式检测视网膜神经纤维层(retinal nerve fiber layer,RNFL)厚度时受视盘大小的影响程度。方法按视盘面积将年龄18~30岁的156名正常人156眼分为大视盘组、中视盘组、小视盘组。应用OCT三种不同模式[RNFL厚度(3.4)扫描模式、视神经盘圆(0.98+视盘半径)扫描模式、RNFL厚度(2.27×disc)扫描模式],分别检测3组受试者全周RNFL厚度。比较同一扫描模式不同组间所测全周RNFL厚度差别。并分析OCT三种扫描模式检测所得全周平均RN-FL厚度值与视盘面积的相关性。结果 RNFL厚度(3.4)扫描模式所测全周平均RNFL厚度不同组间比较,差异有显著统计学意义(F=23.762,P=0.000):大视盘组所测值最大,中视盘组次之,小视盘组最小(P〈0.001)。RNFL厚度(2.27×disc)扫描模式(F=0.738,P=0.416)及视神经盘圆(0.98+视盘半径)扫描模式(F=1.091,P=0.339)所测全周RNFL厚度在各组间比较,差异均无统计学意义。全周平均RNFL厚度值与视盘面积相关性分析,RNFL厚度(3.4)扫描模式所测值与之成正相关(r=0.506,P=0.000);RNFL厚度扫描模式(2.27×disc)所测值与之成负相关(r=-0.290,P=0.001);视神经盘圆扫描模式(0.98+视盘半径)所测值与之无相关性(r=-0.005,P=0.949)。结论 RNFL厚度(3.4)扫描模式检测RNFL厚度受视盘大小影响最大,OCTRNFL厚度(2.27×disc)扫描模式及视神经盘圆(0.98+视盘半径)扫描模式次之,临床应用需注意。 Objective To investigate the influence of optic disc on the retinal nerve fiber layer(RNFL)thickness measured by three different optical coherence tomography(OCT)scanning patterns.Methods According to the optic disc area,156 eyes of 156 healthy subjects from 18 to 30 years old were divided into 3 groups,big disc group,middle disc group and small disc group.Using 3 kinds of OCT scan protocols[RNFL thickness(3.4),nerve head circle(0.98+optic radius)and RNFL thickness(2.27×disc)] to measure the 360° average RNFL thickness of three groups,respectively.The differences between each two groups were compared using the same OCT scanning pattern.The correlations between 360° average RNFL thickness measured by three OCT scanning patterns and the optic disc area were analyzed.Results The 360° average RNFL thickness measured by RNFL thickness(3.4)scanning pattern among three groups had statistically significant differences(F=23.762,P=0.000).The big optic disc group is the biggest one,the middle optic disc group is the next,the small optic disc group is the smallest one(P0.001).The 360° average RNFL thickness measured by RNFL thickness(2.27×disc)scanning pattern and nerve head circle(0.98+optic radius)scanning pattern among 3 groups had no statistically significant difference(F=0.738,P=0.416;F=1.091,P=0.339).A positive correlation was observed between the 360° average RNFL thickness measured by RNFL thickness(3.4)scanning pattern and the optic disc area(r=0.506,P=0.000).A negative correlation was observed between the 360° average RNFL thickness measured by RNFL thickness(2.27×disc)scanning pattern and the optic disc area(r=-0.290,P=0.001).No correlation was observed between the 360° average RNFL thickness measured by nerve head circle(0.98+optic radius)scanning pattern and the optic disc area(r=-0.005,P=0.949).Conclusions The influence of optic disc on RNFL thickness measured by RNFL thickness(3.4)scanning pattern is the biggest one.RNFL thickness(2.27×disc)scanning pattern and nerve head circle(0.98+optic radius)scanning pattern are following.More attention should be paid in clinical application.
出处 《眼科新进展》 CAS 北大核心 2010年第11期1039-1042,共4页 Recent Advances in Ophthalmology
关键词 光学相关断层扫描 视网膜神经纤维层 视盘 模式 optical coherence tomography retinal nerve fiber layer optic disc pattern
  • 相关文献

参考文献1

二级参考文献21

  • 1徐亮,陈建华,李建军,罗灵,杨桦,张蓉秀,孙秀英,郑远远,宋维贤,施玉英,张士元,孙葆忱,赵家良,马斌荣.北京农村及城市特定人群原发性开角型青光眼的患病率调查及其筛查方法评价[J].中华眼科杂志,2004,40(11):726-732. 被引量:80
  • 2徐亮,张莉,夏翠然,李建军,胡莲娜,马科,陈英杰,范桂芝,宋维贤,施玉英,张士元,孙宝忱.北京农村及城市特定人群原发性闭角型青光眼的患病率及其影响因素[J].中华眼科杂志,2005,4(1):8-14. 被引量:64
  • 3刘苏,方谦逊.微机图像处理系统对正常人眼和青光眼视乳头表面参数的测量及分析[J].中华眼科杂志,1993,29(2):71-75. 被引量:3
  • 4Spaeth GL,Henderer J, Steinmann W. The Disc Damage Likelihood Scale (DDLS): its use in the diagnosis and management of glaucoma [J ]. Highlights of Ophthalmology, 2003,10: 4-19.
  • 5Jonas JB, Thomas R, George R, et al. Optic disc morphology in south India: the Vellore Eye Study [J]. Br J Ophthalmol,2003,87:189-196.
  • 6Varma R, Tielsch JM, Quigley HA, et al. Race-, age , gender-, and refractive error-related differences in the normal optic disc [ J ].Arch Ophthalmol, 1994,112:1068-1076.
  • 7Ramrattan RS, Wolfs RCW, Hofmann A, et al. Determinants of optic disc characteristics in a general population. The Rotterdam Study [J ]. Ophthalmology, 1999,106:1588-1596.
  • 8Jonas JB, Gusek GC, Guggenmoos-Holzmann I, et al. Variability of the real dimensions of normal human optic discs [J ]. Graefes Arch Clin Exp Ophthalmol, 1988,226: 332-336.
  • 9Jonas JB, Gusek GC, Naumann GOH. Optic disc, cup and neuroretinal rim size, configuration and correlations in normal eyes [J ]. Invest Ophthalmol Vis Sci, 1988,29:1151-1158.
  • 10Caprioli J, Miller J. Videographic measurements of optic nerve topography in glaucoma [J ]. Invest Ophthalmol Vis Sci, 1988,29:1294-1298.

共引文献9

同被引文献14

引证文献2

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部