在汽液两相分离流动模型的基础上,建立了垂直管内蒸汽冷凝回流阻液分析模型。采用该模型对单根U型管内蒸汽冷凝回流实验参数下的阻液起始点进行计算,计算结果与实验结果符合较好。分析模型还与现有分析模型和经验关系式进行了比较,结果表明,本模型与DuklerSmith关系式符合较好,而与Kutateladez类型关系式和其它分析模型的偏差相对较大。
An analytical model for the flooding of reflux condensation in a vertical tube was proposed based on the seperated flow models.Calculation results show that the present model predicts well the experimental data obtained in a single inverted U tube,and agrees well with the Dukler Smith correlation.However,the discrepancies between the present model and the Kutateladze's type of correlation,and other analytical models are great.
出处
《核动力工程》
EI
CAS
CSCD
北大核心
1999年第3期223-227,共5页
Nuclear Power Engineering
关键词
分析模型
冷凝回流
阻液起始点
相间阻力
压水堆
Analytical model Reflux condensation Onset of flooding Interfacial friction