摘要 磁性部件柜是核动力装置重要的热控装置之一,由于原磁性部件柜是以自饱和磁放大器为基本元件,因而具有一定的缺陷。为了进一步提高核动力装置的安全可靠性,必须对原磁性部件柜进行技术改进。研制与原磁性部件柜性能相同的新型部件,取代原磁性部件柜,将磁性元件全部改成集成电路组成的各功能部件。本文全面分析了原磁性部件柜失效的原因,并提出了具体的改进措施。 The magnetic component cabinet is an important thermal control device fitted on the nuclear power.Because it used a self saturation amplifier as a primary component,the magnetic component cabinet has some boundedness.For increasing the operation safety on the nuclear power,the paper describes a new scheme.In order that the magnetic component cabinet can be replaced,the new type component cabinet is developed.Integrate circuit will replace the magnetic components of every function parts.The paper has analyzed overall failure cause for magnetic component cabinet and adopted some measures.
作者 葛兵
机构地区 海军工程学院
出处 《核动力工程》 EI CAS CSCD 北大核心 1999年第3期277-280,共4页 Nuclear Power Engineering
关键词 磁性部件柜 失效原因 改进 核动力 热控装置 Magnitic component cabinet Failure cause Improvement