期刊文献+

医院输液泵质量控制检测与体会 被引量:10

Experience and Measurement of Infusion Pump Quality Control in Hospital
下载PDF
导出
摘要 目的:分析输液泵质量控制检测中遇到的问题,提出影响输液泵质量检测结果判定的主要因素。方法:采用美国Fluke公司Metron lagu1型输液泵检测仪在不同的条件下对贝郎输液泵进行检测实验和对比测试。结果:总结出了进行输液泵质量控制检测时应具备的条件和评定方法。结论:输液泵的应用质量检测条件应结合临床实际,在不同的检测条件下,输液泵检测结果会有很大差异。 Objective On the basis of analyzing the problems encountered during quality control testing of infusion pump,to propose the main factors affecting the results of infusion pump quality control testing.Methods FLUKE Metron lagu1 was used to detect the Tony Lang infusion pumps in different conditions.Results Qualifications and assessment methods of infusion pump during the process of quality control testing were put forward and described in detail.Conclusion Infusion pump quality control testing should accord with clinical practice.Huge differences of testing results are in place due to different conditions.
出处 《医疗卫生装备》 CAS 2010年第11期134-136,共3页 Chinese Medical Equipment Journal
关键词 输液泵 质量控制 检测 影响因素 infusion pump quality control detection influencing factors
  • 相关文献

参考文献6

二级参考文献6

  • 1侯艺威,郑吉锋,刘小丽,张玉洁.输液泵使用不同泵管的测试[J].医疗设备信息,2005,20(6):71-72. 被引量:25
  • 2国际电工委员会.IEC 60601-2-24 Medical electrical equipment - Part 2- 24: Particular requirements for the safety of infusion pumps and controllers,1998.02.
  • 3费业泰.误差理论与数据处理(第3版)[M].北京:机械工业出版社,1995.
  • 4许跃民,刘群.GB9706.27-2005/IEC 60601-2-24:1998(医用电气设备第2-24部分:输液泵和输液控制器安全专用要求》.
  • 5《METRON lagu1输液泵质量检测仪说明书》.
  • 6费业泰.误差理论与数据处理[M]机械工业出版社,2000.