期刊文献+

双源CT的核心技术与临床应用 被引量:6

Double source CT core technologies and clinical applications
下载PDF
导出
摘要 双源CT的出现解决了传统多层CT技术不能解决的问题,是CT领域十分重要的进展,将指引CT新的发展方向。西门子SOMATOM Definition Flash系统通过二套X射线源和探测器,完成心脏扫描,独特的双能量技术可以对心率过快、不规则心率及屏气有困难的患者进行扫描,克服了传统64层CT需要服药控制心率的弊端。图像质量明显提高,比常规CT具有更多的优势和临床应用功能,同时还可进行其它方面的成像研究。 The development of double source CT is an important advancement in CT technology since it can solve those problems that can not be solved by conventional multi-slice CT. Through two sets of X-ray source and detector, Siemens SOMATOM Definition Flash the system can show the details of the heart SOMATOM Definition Flash with 75 ms time resolution. Dual-source CT image quality is significantly improved compared with conventional CT. Dual Source CT can be used in patients with fast heart rate, irregular heart rate and breath holding.Dual Source CT can clearly show the coronary artery, so it can be used for multi-slice reconstruction.
出处 《中国医学装备》 2010年第11期55-57,共3页 China Medical Equipment
关键词 双源CT 核心技术 扫描剂量 双能量技术 Dual-source CT Core technology Scanning dose Dual-energy technology
  • 相关文献

参考文献5

  • 1www. siemens, com/healthcare www. siemens, com/somatom definition-flash.
  • 2www. medical, siemens, com/webapp/ wcs/stores/servlet/ProductDisplay-q_ catalogld-e -8-a_ catTree-e_100010,100 7660,12732,1008408-a langld-e_8-a productld-e_ 187741 -a storeld-e_10001 .htm.
  • 3www.medical.siemens.com/webapp/ wcs/stores/servlet/ProductDisplay-qcatalogId~e -8~a catTree~e_100010,100 7660,12752,1008408~a langId~e_ 8~a_ productId~e 187741 ~a storeId~e 10001. htm.
  • 4李若梅,王嗣伟.双源CT的结构和技术特点及其临床应用[J].实用医学影像杂志,2009,10(6):395-397. 被引量:3
  • 5郑玲,顾海峰,杨刚,李林,周长圣,张龙江,卢光明.双源CT成像技术及其临床应用的新进展[J].医学研究生学报,2008,21(4):404-407. 被引量:46

二级参考文献28

  • 1石明国,张振荣,尤志军,郑敏文.CT成像技术的发展[J].中国医学装备,2007,4(4):56-60. 被引量:25
  • 2张宗军,卢光明.双源CT及其临床应用[J].医学研究生学报,2007,20(4):416-418. 被引量:106
  • 3Flohr TG, McCollough CH, Bruder H,et al. First performance evaluation of a dual-source CT (DSCT) system[J]. Eur Radiol, 2006,16 (2) : 256-268.
  • 4Scheffel H,Alkadhi H,Plass A,et al. Accuracy of dual-source CT coronary angiography: first experience in a high pre-test probability population without heart rate control [J]. Eur Radiol, 2006,16(11): 2739-2747.
  • 5郭华,张龙江,江时森,王立军,钟勇,汤沂,卢光明.双源CT成像在评价冠状动脉狭窄中价值的初步探讨[J].医学研究生学报,2007,20(7):727-730. 被引量:46
  • 6Scheffel H, Alkadhi H, Plass A, et al. Accuracy of dual-source CT coronary angiography: first experience in a high pre-test probability population without heart rate control [ J ]. Eur Radiol, 2006,16(12) :2739-2747.
  • 7Raff GL, Gallagher MJ, O' Neill WW, et al. Diagnostic accuracy of noninvasive coronary angiography using 64-slice spiral computed tomography [ J ]. Am Coll Cardiol, 2005,46 ( 1 ) : 552-557.
  • 8Flohr TG, McCollough CH, Bruder H, et at. First performance evaluation of a dual-source CT (DSCT) system[J]. Eur Radial, 2006,16(2) :256-268.
  • 9Johnson TR, Nikolaou K, Leber AW, et al. Dual-source CT cardiac imaging: initial experience [ J ]. Eur Radial, 2006,16 (7) : 1409-1415.
  • 10Leschka S, Alkadhi H, Plass A, et al. Accuracy of MSCT coronary angiography with 64-slice technology : first experience [ J ]. Eur Heart J, 2005, 26(15) : 1482-1487.

共引文献47

同被引文献48

引证文献6