摘要 目的:使用自行研制的射野验证软件(EMRT)对头颈肿瘤放疗的摆位误差进行分析,探讨其实际应用价值。方法:将接受头颈部放射治疗的35例患者模拟定位和治疗摆位的射野验证照片,扫描输入EMRT软件进行中心点摆位误差分析,并与常规人工方法分析的摆位误差相比较。结果:35例患者的射野中心点在X轴的摆位误差,采用EMRT软件及常规人工方法进行分析的结果相似(1.36±1.60)mmvs(1.37±1.72)mm,t=0.18,P=0.86,而在Y轴的摆位误差的结果也相似(0.59±1.85)mmvs(0.53±1.89)mm,t=1.30,P=0.20。结论:与常规人工方法相比较,采用EMRT软件进行头颈部肿瘤放射治疗摆位误差分析方法简便、结果可靠,可作为头颈部肿瘤放射治疗摆位验证的快速工具。 OBJECTIVE:To evaluate the application of EMRT software in set-up verification of radiotherapy treatment for head and neck cancer. METHODS: Simulation and portal films under treatment positioning of 35 patients who were received radiotherapy for head and neck cancer were scaned and input to the EMRT software. Positioning errors were analyzed with the software and compared with the results of conventional manual measurement. RESULTS: The set-up deviation from the beam center measured by EMRT was similar to that by manual inspection in both X-axis (1.36±1.60) mm vs (1.37±1.72) mm, t=0.18, P=0.86, and similar in Y-axis (0.59±1.85) mm vs (0.53±1.89) mm, t=1.30, P=0.20. CONCLUSION:The EMRT software is convenient and reliable to analyze the set-up deviation in radiotherapy for head and neck treatment, and it can be used as a rapid tool for set-up verification in radiation treatment of head and neck cancer.
出处 《中华肿瘤防治杂志》 CAS 2010年第19期1555-1557,共3页 Chinese Journal of Cancer Prevention and Treatment
基金 广东省科技计划资助项目(2007B031516004)
关键词 头颈部肿瘤/放射疗法 体位 计算机辅助设计 软件设计 head and neck neoplasms/radiotherapy posture computer aided design software design
  • 相关文献

参考文献5

二级参考文献17

  • 1沈君姝,王健琪,张宜勤,翟振宇,荆西京.头颈部肿瘤调强放疗中摆位偏差的测量与分析[J].第四军医大学学报,2006,27(12):1147-1149. 被引量:24
  • 2潘才住,潘建基,陈传本,张秀春,李金莲.电子射野影像系统测量鼻咽癌调强放疗的摆位误差[J].福建医科大学学报,2007,41(1):49-52. 被引量:24
  • 3[2]Kinxie JJ, Hanks GE, Maclean, CJ et al. Patterns of care study: Hodgkin's Disease relapse rates and adequacy of portals[J]. Cancer, 1983, 52:2223-2226.
  • 4.调强适形放射治疗[A].胡逸民.肿瘤放射物理学[C].北京:原子能出版社,1999.538-612.
  • 5Prescribing recording and reporting photon beam therapy [R]. ICRU. Report no.50. 1993.
  • 6Prescribing recording and reporting photon beam therapy (Supplement to ICRU report 50) [R]. ICRU. Report no. 62. 1999.
  • 7Van Herk M, Remeijer P, Lebesque Jr. Inclusion of geometric uncertainties in treatment plan evaluation [J]. Int J Radiat Oncol Biol Phys, 2002,52(5):1407-1422.
  • 8Mckenzie A, Van Herk M, Mijnheer B. Margins for geometric uncertainty around organs at risk in radiotherapy [J]. Radiotherapy and Oncology, 2002,62(3):299-307.
  • 9Hurkmans CW, Remeijer P, Lebesque JV, et al. Set-up verification using portal images review of current clinical practice [J]. Radiotherapy and Oncology, 2001,58(2):105-120.
  • 10Stroom JC, de Boer HC, Huizenga H, et al. Inclusion of geometrical uncertainties in radiotherapy treatment planning by means of coverage probability [J]. Int J Radiat Oncol Biol Phys. 1999,43(4):905-919.

共引文献64

同被引文献65

  • 1庞学利,阮志华,肖红,王希,谭崇富,曾勇.鼻咽癌不同立体加量照射方法临床剂量学比较研究[J].中国医学物理学杂志,2006,23(1):12-15. 被引量:5
  • 2戴建荣,胡逸民.图像引导放疗的实现方式[J].中华放射肿瘤学杂志,2006,15(2):132-135. 被引量:184
  • 3Kam MK, Chau RM, Suen J, et al. Intensity-modulated radio therapy in nasopharyngeal carcinoma., dosimetrie advantage over conventional plans and {easibility of dose escalation[J].Int J Ra diat Oncol Biol Phys, 2003,56 ( 1 ) : 145.
  • 4Stroom JC, Heijmen BJ. Geometrical uncertainties, radiotherapy planning margins,and the ICRU-62 report [J].Radiother Oncol, 2002,64(1) :75-83.
  • 5Siebers JV,Keall PJ,Wu Q,et al. Effect of patient setup errors on simultaneously integrated boost head and neck IMRT treat- ment plans[J]. Int J Radiat Oncol Biol Phys, 2005,63 (2) : 422 -433.
  • 6WulfJ, Hadinger U, Oppitz U, et al. Impact of target reproduc?ibility on tumor dose in stereotactic radiotherapy of targets in the lung and liver[J]. Radiother Oncol,2003,66(2): 141-150.
  • 7Tsai]S, Micaily B, Miyamoto C, et al. Optimization and quality assurance of an image-guided radiation therapy system for inten?sity-modulated radiation therapy radiotherapy[J]. Med Dosim , 2012,37(3):321-333.
  • 8Burridge N, Amer A, Marchant T, et al. Online adaptive radio?therapy of the bladder: small bowel irradiated-volume reduction[J]. IntJ Radiat Oncol BioI Phys,2006,66(3) :892-897.
  • 9WongJW,Sharpe MB,Jaffray DA,et al. The use of active breathing control (ABC) to reduce margin for breathing motion[J]. IntJ Radiat Oncol BioI Phys,1999,44(4) :911-919.
  • 10Chen AM, Farwell DG, Luu Q, et al. Evaluation of the planning target volume in the treatment of head and neck cancer with in?tensity-modulated radiotherapy: what is the appropriate expan?sion margin in the se.

引证文献5

二级引证文献22

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部