摘要
从锅炉结构入手,分析了HG-240/9.8-L.MG35型循环流化床锅炉外循环不稳定的原因,并给出了解决方案和调控手段。
Starting from the boiler's structure, this article analyzed the causes of the instability of the HG-240/ 9.8-L.MG35 circulating fluidized bed boiler's outer loop, and also gave the countermeasures.
出处
《同煤科技》
2010年第2期20-22,共3页
Datong Coal Science & Technology
关键词
蒸汽锅炉
循环流化床锅炉
外循环
外循环不稳定
steam boiler
circulating fluidized bed boiler
outer loop
outer loop unstable