期刊文献+

A350LF2钢在湿H_2S环境中的力学性能损伤 被引量:1

Degradation of mechanical properties of A350LF2 steel in environment with H_2S
下载PDF
导出
摘要 研究了腐蚀时间、溶液温度、pH值对A350LF2钢在湿H2S环境中力学性能的影响。结果表明:H2S腐蚀后,A350LF2钢的力学性能变化不但与腐蚀环境密切相关,还与腐蚀后力学性能的测试周期密切相关。材料的抗拉强度、屈服强度等性能随环境条件变化呈现不同的变化规律,并且发现腐蚀后立刻进行的性能测试表明,力学性能损伤比较严重;而腐蚀后放置一段时间后的力学性能测试结果表明,损伤的力学性能不同程度得到恢复,甚至达到腐蚀前材料的力学性能。结合扩散氢测试结果分析认为,A350LF2钢力学损伤程度与钢中氢含量密切相关。 Evolution law of mechanical properties of A350LF2 steel in wet hydrogen sulfide environment was investigated.The effects of corrosion time,solution temperature and pH value on mechanical properties of the steel were examined.The results show that not only the corrosion environment but also delay time tensile testing after etching can affect the mechanical properties of A350LF2 steel after H2 S corrosion.The tensile strength and yield strength of the steels present different variation rules in different environments.Moreover,the result of tensile test that was carried out immediately after corrosion show that the degradation of mechanical properties of the steels is serious.However,laying specimens for certain time after etching,the tensile test results indicate that the degraded mechanical properties can be partially recovered,and even more to the state before corrosion.Combining with diffusible hydrogen test results,it is suggested that the degradation degree of mechanical properties of A350LF2 steel depends on hydrogen content of steels.
出处 《材料热处理学报》 EI CAS CSCD 北大核心 2010年第11期99-103,共5页 Transactions of Materials and Heat Treatment
基金 国家自然科学基金(50871122)
关键词 碳钢 氢致损伤 力学性能 H2S carbon steel hydrogen-induced damage mechanical properties H2S
  • 相关文献

参考文献9

  • 1尹成先,兰新哲,霍春勇,冯耀荣.影响油气输送管线抗HIC因素探讨[J].焊管,2002,25(5):20-24. 被引量:19
  • 2翁永基.管道钢氢损伤(HIC)的机埋、控制因素及评价方法.油气储运,1986,5(1):23-28.
  • 3Vedapuri D, Kang C, Dhanabal D, et al. Inhibition of muhiphase wet gas corrosion[ C ] ffCorrosion, 2000:118 - 129.
  • 4YIN Z F, ZHAO W Z, et al. Corrosion behavior of SM 80SS tube steel in stimulant solution containing H2S and CO2 [ J]. Electrochimica Acta, 2008, 53:3690 - 3700.
  • 5Metallic materials-tensile testing at ambient temperature[ S ]. GB/T 228 -2002.
  • 6Evaluation of pipeline and pressure vessel steels for resistance to Hydrogen-induced cracking[ S]. NACE Standard TM0284 -2003.
  • 7Laboratory testing of metals for resistanc e to sulfide stress cracking and stress corrosion cracking in H2S environments[ S]. NACE Standard TM0177 - 2005.
  • 8PAN C, SU Y J, CHU W Y, et al. Hydrogen embrittlement of weld metal of austenitic stainless steels[J]. Corros Sci, 2002,44 : 1983.
  • 9Kimura H, Matsui H. Mechanism of hydrogen-induced softening and hardening in iron [ J ]. Scripta Metallurgica, 1987,21:319 - 324.

二级参考文献2

共引文献18

同被引文献7

引证文献1

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部