本文提出了超过滤的模型,通过对苯二甲酸悬浮液的超滤浓缩数据的线性回归,提出了对该体系的污染方程系数,利用此模型计算了操作参数变化对超滤通量的影响曲线,求出了最佳操作条件。
In this paper, membrane fouling model is presented. Membrane coefficients were obtained by linear regression method for ultrafiltration of the waste water containing terephthalic acid. The optimized operating conditions were simulated. The model can be used to design ultrafiltration process for similar liquid mixtrure systems.
出处
《水处理技术》
CAS
CSCD
1999年第3期144-147,共4页
Technology of Water Treatment
关键词
超滤膜
对苯二甲酸
膜污染
模型
指数模型
Ultrafiltration, Membrane fouling, Terephthalic acid, Model