期刊文献+

系统级定标方法实现基于低温辐射计的标准灯400~900nm波段光谱辐照度 被引量:6

400~900 nm Spectral Irradiance of Cryogenic Radiometer-Based Irradiance Standard Lamp Using System Level Calibration Method
原文传递
导出
摘要 为提高光辐射工作标准精度和满足遥感器高精度辐射定标需要,开展了以低温辐射计为初级标准,滤光片辐射计为传递标准的标准灯光谱辐照度实现研究。通过滤光片辐射计响应的系统级定标、辐照度标准灯物理模型和递归迭代优化算法,由滤光片带宽下的积分响应得到辐照度标准灯的连续光谱分布。系统级的定标方法避免了滤光片透射率、几何因子测量和使用与标定状态不一致引入的不确定度。初步结果表明,该方法实现的400~900 nm波段标准灯光谱辐照度与基于国际温标(ITS-90)高温黑体标定的结果相对差别在后者的不确定度范围之内。在国内尝试实现了基于低温辐射计的标准灯光谱辐照度标准传递,对提高光辐射计量、辐射测温以及遥感器特别是高光谱遥感器辐射定标精度有重要意义。 To improve the accuracy of radiation work standards and meet the urgent need of high-accuracy remote sensors calibration,a study about establishment of irradiance of standard lamp with spectrum range from 400 to 900 nm is carried out using the cryogenic radiometer as the primary standard and filter radiometer as the transfer standard.Through with a recursive iterative optimization algorithm,a physical model of the irradiance standard lamp and a filter detector spectral response system level calibration by a laser imported integrating sphere,the continuous spectral distribution of the irradiance standard lamp can be calculated.The method of system level calibration avoids the uncertainty induced by filter transmittance,geometric factor measurement uncertainty and discord between use and calibration states.Preliminary results show that the difference between standard lamp irradiance calibrated by ITS-90 black body and calculated value by the method is within the uncertainty of calibration.The transfer stand of an irradiance standard lamp based on cryogenic radiometer is tried in China.The method could greatly improve the accuracy of current optical radiation work standard.The research has important significance in the optical radiation measurement and remote sensors,especially in hyper-spectral remote sensors calibration.
出处 《光学学报》 EI CAS CSCD 北大核心 2010年第11期3349-3353,共5页 Acta Optica Sinica
关键词 遥感 低温辐射计 辐射定标 高光谱遥感 光谱辐照度 定量遥感 系统级定标 remote sensing cryogenic radiometer radiometric calibration hyper-spectral remote sensing spectral irradiance quantitative remote sensing system level calibration
  • 相关文献

参考文献17

  • 1J. C. Bremer, J. C. Criscione, M. S. Maxwell et al.. Calibration of the solar reflective channels in an integrated operational weather satellite system in the era of NPOESS and GOES-R[C]. SPIE, 2005, 5658: 38.
  • 2H. J. Kostkovski. Reliable Spectroscopy [M]. Maryland: Spectroradiometry Consulting, 1997. 162.
  • 3郑小兵,吴浩宇,章骏平,周威,刘玉成,王乐意,乔延利.不确定度优于0.035%的绝对光谱响应率标准探测器[J].光学学报,2001,21(6):749-752. 被引量:65
  • 4周磊,彭妮娜,张黎明,吴浩宇,郑小兵.基于标准探测器的FY-2(05)星扫描辐射计可见通道外场定标[J].遥感技术与应用,2007,22(1):20-25. 被引量:6
  • 5J. J. Butler, B. L. Markham, B. C. Johnson et al.. Radiometric measurement comparisons using transfer radiometers in support of the calibration of NASA′s earth observing system (EOS) sensors[C]. SPIE, 1999, 3870: 180.
  • 6J. Metzdorf, A. Sperling, S. Winter et al.. A new FEL-type quartz-halogen lamp as an improved standard of spectral irradiance [J]. Metrologia, 1998, 35(4): 423-426.
  • 7T. Kübarsepp, H. W. Yoon, S. Nevas et al.. Comparison of spectral irradiance scales between the NIST and the HUT[J]. Metrologia, 2002, 39(4): 399-402.
  • 8Y. J. Liu, G. Xu, M. Ojanen et al.. Spectral irradiance comparison using a multi-wavelength filter radiometer[J]. Metrologia, 2009, 46(S1): 81-85.
  • 9P. Krh, P. Toivanen, F. Manoochehri et al.. Development of a detector-based absolute spectral irradiance scale in the 380-900-nm spectral range[J]. Appl. Opt., 1997, 36(34): 8909-8918.
  • 10J. C. Lagarias, J. A. Reeds, M. H. Wright et al. Convergence properties of the nelder-mead simplex method in low dimensions[J]. SIAM J. Optim., 1998, 9(1): 112-147.

二级参考文献23

  • 1李双,王骥,章骏平,吴浩宇,郑小兵.可见-近红外(488~944nm)基于低温辐射计的高精度光辐射绝对定标研究[J].光学学报,2005,25(5):609-613. 被引量:17
  • 2邾继贵,王大为,王鑫,叶声华.光学坐标测量系统中的关键技术[J].红外与激光工程,2007,36(3):296-299. 被引量:19
  • 3WooUiams E R, Cox M G, Fox N P, et al. CIPM Key Comparison K1-a Spectral Irradiance 250nm to 2500nm Final Report[ R]. 2006.
  • 4WoolliamsE R , Fox N P, Cox M G, et al. TheCCPR K1-a key comparison of spectral irradiance from 250nm to 2500nm : measurements, analysis and results [ J ]. Metrologia, 2006, 43 ( 2 ) : S98 - S104.
  • 5Huang L K, Cebula R P, Hilsenrath E. New procedure for interpolating NIST FEL lamp irradiances [ J ]. Metrologia, 1998, 35(4): 381 -386.
  • 6Andor G. Approximation function of spectral irradiance of stand lamps[J]. Metrologia, 1998, 35(4) : 427 -429.
  • 7Larason T. C., Bruce S. S., Parr A. C., Spectroradiometric Detector Measurements, Natl. Inst. Stand. Technol. Spec. Publ. 250-41, US Government Printing Office, Washington, DC, 1998
  • 8G. Eppeldauer, M. Racz, T. Larason, Optical characterization of diffuser-input standard irradiance meters[C] SPIE, 1998, 3573: 220-224
  • 9K. D. Mielenz, R. D. Saunders, J. B. Shumaker, Spectroradiometric Determination of the Freezing Temperature of Gold[J]. J. Res. Natl. Inst. Stand. Technol, 1990, 95: 49-67
  • 10Anderson V. E., Fox N. P., Nettleton D. H., Highly stabel, monochromatic and tunable optical radiation source and its application to high accuracy spectrophotometry[J]. Appl. Opt., 1992, 31(4): 536-545

共引文献84

同被引文献63

  • 1Zhengqiang Li,Luc Blarel,Thierry Podvin et al..Transferringthe calibration of direct solar irradiance to diffuse-sky radiancemeasurements for CIMEL sun-sky radiometers[J].Appl.Opt.,2008,47(10):1368-1377.
  • 2Beat Schmid,Christoph Wehrli.Comparison of sun photometercalibration by use of the Langley technique and the standard lamp[J].Appl.Opt.,1995,34(21):4500-4512.
  • 3Steven W.Brown,George P.Eppeldauer,Joseph P.Rice et al..Spectral irradiance and radiance responsivity calibrations usinguniform sources(SIRCUS)facility at NIST[C].SPIE,2004,5542:363-374.
  • 4Steven W.Brown,George P.Eppeldauer,Keith R.Lykke.Facility for spectral irradiance and radiance responsivitycalibrations using uniform sources[J].Appl.Opt.,2006,45(32):8218-8237.
  • 5Jinan Zeng,Howard W.Yoon,George P.Eppeldauer et al..Spectral irradiance responsivity calibration of InSb radiometersusing the improved IR-SIRCUS at NIST[C].SPIE,2009,7453:74530N.
  • 6Ville Ahtee,Steven W.Brown,Thomas C.Larason et al..Comparison of absolute spectral irradiance responsivitymeasurement techniques using wavelength-tunable lasers[J].Appl.Opt.,2007,46(20):4228-4236.
  • 7B.Muralikrishnan,J.A.Stone,J.R.Stoup.Areameasurement of knife-edge and cylindrical apertures using ultra-low force contact fibre probe on a CMM[J].Metrologia,2008,45(3):281-289.
  • 8E.Ikonen,P.Toivanen,A.Lassila.A new optical method forhigh-accuracy determination of aperture area[J].Metrologia,1998,35(4):369-372.
  • 9CIMEL Corporation SunPhotometer User Manual.Version 4.6[M].Paris:CIMEL electronique,2001.
  • 10American Society for Testing and Materials.2000 ASTMStandard Extraterrestrial Spectrum Reference E-490-00[EB/OL].http://rredc.nrel.gov/solar/spectra/am0/ASTM2000.html,2000.

引证文献6

二级引证文献36

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部