摘要 介绍了偏二甲肼、甲基肼和无水肼三种渗透管温度对其渗透率的影响。研究结果表明,在25℃~45℃之间,渗透率的对数与温度呈良好的线性关系,符合渗透机理,并得出了温度波动0.1℃时,其渗透率的变化分别为0.65%,0.65%和0.76%,同时测定了温度循环变化时,渗透率是能再现的。 The effect of the temperature on the permeation rate for the UDMH, MMH and Hz permeation tubes is presented in this paper. The research results show that the variation of logarithm of permeation rate with the temperature is linear under 25 ℃~40 ℃, and accords with the permeation mechanism. The changes of their permeation rates are 0.65%,0.65% and 0.76% separately for UDMH, MMH and Hz when the temperature fluctuation is in 0.1 ℃. The permeation rate can be reproduced when the change of temperature cycle is measured.
作者 吕玉兰
出处 《导弹与航天运载技术》 1999年第3期47-54,共8页 Missiles and Space Vehicles
关键词 肼衍生物 渗透率 气体分析 推进剂 Hydrazine derivate, Permeability, Gas analysis.
  • 相关文献

同被引文献14

  • 1康小录.航天器被动检漏技术[J].中国空间科学技术,1996,16(3):39-44. 被引量:1
  • 2蒋俭 等.火箭推进剂监测防护与污染处理[M].长沙:国防科技大学出版社,1993..
  • 3(美)奥汉隆 胡炳森译.真空技术实用指南[M].北京:国防工业出版社,1988.84.
  • 4康小录.质谱定量分析及其在卫星推进剂泄漏检测中的应用.中国空间技术研究院青年论文报告会[M].北京,1995,1..
  • 5于义朋,杨国栋.微量水测量的计量保证[R].北京:中国计量科学研究院,1986.
  • 6顾继承.YH-ST08标准湿度发生器研制报告[R].北京:中航工业北京长城计量测试.
  • 7MATTSON C B, HAMMOND T A, SCHWINDT C J. Automated test systems for toxic vapor detectors[R]. NASA-CR-203811, 1997.
  • 8BARILE R G, HODGE T R, MENEGHELLI B J. Sample diluter for detecting hypergolic propellants and other toxic or hazardous gases[R]. NASA-CR-203969, 1997.
  • 9STETTER J R, LAU Y K. Toxic level hypergolic vapor detection sensor development[R]. N80-18366, 1979.
  • 10ISO 6145 - 1998 Gas anaLysis: Preparation of calibratrion gas mixture-dynamic volumetric method [ S] . 1998.