600 MW超临界机组无辅助汽源热态启动方案的探索与实践 被引量:1

Research on Hot Start-up Program of 600 MW Supercritical Unit without Auxiliary Steam Source
原文传递
导出
摘要 针对没有辅助汽源的600 MW超临界机组,积极探索了一套有针对性的启动方案。通过分析实践过程中存在的问题,提出防范措施,实现了机组热态的快速启动,既节约了生产成本,又缩短了启动时间,取得了良好的经济效益和社会效益。实践方案对国内同类型机组具有较好的借鉴意义。 This paper explored a targeted start-up program with respect to the 600 MW supercritical units,which do not have auxiliary steam source systems.Through the analysis on practical problems,preventive measures were proposed,and a rapid hot-start program was realized;and thus the production cost can be saved,and the startup time can be shortened,which will achieve good economic and social benefits,and provide reference for units with the same type.
出处 《电力建设》 2010年第12期112-114,共3页 Electric Power Construction
关键词 辅助汽源 热态启动 超临界机组 锅炉点火 汽缸 主蒸汽 auxiliary steam source hot start-up supercritical unit boiler ignition cylinder main steam
  • 相关文献

参考文献3

  • 1皖能合肥发电有限公司.5号机组集控运行规程[R].合肥:皖能合肥发电有限公司,2008.
  • 2谢诞梅,杜杰.600MW超临界火力发电机组技术丛书:汽轮机设备与系统[M].武汉:武汉大学出版社,2007.
  • 3陈华桂,秦惠敏,卢修连,高远.600MW超临界机组汽轮机中压缸启动分析[J].江苏电机工程,2006,25(2):19-22. 被引量:6