摘要
基于存在增敏剂十六烷基三甲基溴化铵,铬(Ⅵ)催化过氧化氢氧化胭脂红酸的反应,拟定了测定痕量铬(Ⅵ)的新催化光度法。本法由于添加了十六烷基三甲基溴化铵,灵敏度提高3.3倍,测定铬(Ⅵ)含量的线性范围为0.005~0.16μg/mL,检出限为1.0×10-3μg/mL,相对标准偏差为0.5%(n=9),可用于测定水样中的铬(Ⅵ)。
A new catalytic spectrophotometric method for the determination of trace amount of Cr() has been developed. The method is based on the catalytic effect of Cr() on the oxidation of cochineal acid by hydrogen peroxide in the presence of CTMAB as sensitizer.The sensitivity can be increased by 3.3 times after the addition of CTMAB. The linear range of determination is 0.0050.16 g/ mL, the detection limit is 1.010\+\{-3\} g/mL,and the relative standard deviation is 0.5%(n=9). The method can be used for the determination of Cr() in water samples.\=
出处
《分析科学学报》
CAS
CSCD
1999年第3期213-216,共4页
Journal of Analytical Science
基金
福建省自然科学基金
关键词
催化光度法
CTMAB
胭脂红酸
铬
测定
Catalytic spectrophotometry, Hexadecy1 trimethy1 ammonium, Cochineal acid, Chromium