期刊文献+

Analytical solutions of transient pulsed eddy current problem due to elliptical electromagnetic concentrative coils 被引量:2

Analytical solutions of transient pulsed eddy current problem due to elliptical electromagnetic concentrative coils
下载PDF
导出
摘要 The electromagnetic concentrative coils are indispensable in the functional magnetic stimulation and have potential applications in nondestructive testing. In this paper, we propose a figure-8-shaped coil being composed of two arbitrary oblique elliptical coils, which can change the electromagnetic concentrative region and the magnitude of eddy current density by changing the elliptical shape and/or spread angle between two elliptical coils. Pulsed current is usually the excitation source in the functional magnetic stimulation, so in this paper we derive the analytical solutions of transient pulsed eddy current field in the time domain due to the elliptical concentrative coil placed in an arbitrary position over a half-infinite plane conductor by making use of the scale-transformation, the Laplace transform and the Fourier transform are used in our derivation. Calculation results of field distributions produced by the figure-8-shaped elliptical coil show some behaviours as follows: 1) the eddy currents are focused on the conductor under the geometric symmetric centre of figure-8-shaped coil; 2) the greater the scale factor of ellipse is, the higher the eddy current density is and the wider the concentrative area of eddy current along y axis is; 3) the maximum magnitude of eddy current density increases with the increase of spread angle. When spread angle is 180°, there are two additional reverse concentrative areas on both sides of x axis. The electromagnetic concentrative coils are indispensable in the functional magnetic stimulation and have potential applications in nondestructive testing. In this paper, we propose a figure-8-shaped coil being composed of two arbitrary oblique elliptical coils, which can change the electromagnetic concentrative region and the magnitude of eddy current density by changing the elliptical shape and/or spread angle between two elliptical coils. Pulsed current is usually the excitation source in the functional magnetic stimulation, so in this paper we derive the analytical solutions of transient pulsed eddy current field in the time domain due to the elliptical concentrative coil placed in an arbitrary position over a half-infinite plane conductor by making use of the scale-transformation, the Laplace transform and the Fourier transform are used in our derivation. Calculation results of field distributions produced by the figure-8-shaped elliptical coil show some behaviours as follows: 1) the eddy currents are focused on the conductor under the geometric symmetric centre of figure-8-shaped coil; 2) the greater the scale factor of ellipse is, the higher the eddy current density is and the wider the concentrative area of eddy current along y axis is; 3) the maximum magnitude of eddy current density increases with the increase of spread angle. When spread angle is 180°, there are two additional reverse concentrative areas on both sides of x axis.
作者 肖春燕 张军
出处 《Chinese Physics B》 SCIE EI CAS CSCD 2010年第12期30-42,共13页 中国物理B(英文版)
基金 Project supported by the National Natural Science Foundation of China (Grant No. 50807001)
关键词 transient pulsed eddy current analytical solution elliptical electromagnetic concentra-tive coil functional magnetic stimulation transient pulsed eddy current, analytical solution, elliptical electromagnetic concentra-tive coil, functional magnetic stimulation
  • 相关文献

参考文献17

  • 1Iramina K, Maeno T, Nonaka Y and Ueno S 2003 J. Appl. Phys. 93 6718.
  • 2Ueno S, Tashiro T and Harada K 1988 J. Appl. Phys. 64 5862.
  • 3Zhang J Y and Lei Y Z 2007 Nondestructive Testing 29 57.
  • 4Ren C, Tarjan P P and Popovic D B 1995 IEEE Trans. Biomed. Eng. 42 918.
  • 5Hsu K H and Durand D M 2001 IEEE Trans. Biomed. Eng. 48 1162.
  • 6Salinas F S, Lancaster J L and Fox P T 2009 Phys. Med. Biol. 54 3631.
  • 7Lin V W, Hsiao I N and Dhaka V 2000 IEEE Trans. Biomed. Eng. 47 600.
  • 8Ruohonen J and Ilmoniemi R J 1998 Med. Biol. Eng. Comput. 36 297.
  • 9Pu L N , Yin T, An H, Li S and Liu Z P 2008 Journal of Biomedical Engineering Research 27 74.
  • 10Ho S L, Xu G Z, Fu W N, Yang QX, Houri J andYan W L 2009 IEEE Trans. Magn. 45 4849.

同被引文献15

引证文献2

二级引证文献15

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部