负载下碳纤维布约束混凝土方柱的轴压试验 被引量:2

Experimental Research on Axially Loaded Square-section Concrete Columns Confined by Carbon Fiber Reinforced Plastic(CFRP) Under Preload
下载PDF
导出
摘要 碳纤维布约束混凝土柱可以提高其强度和延性,是一种经济、有效的常用加固方法。过去的研究工作大多集中在无负载的混凝土柱,而在实际加固工程中,混凝土柱通常处于负载状态。通过16个碳纤维布约束混凝土方柱的轴压试验,研究了方柱在不同的负载水平和碳纤维包裹层数下的破坏特征和力学性能,并对负载导致约束混凝土峰值点应力和应变下降的原因进行了分析。试验结果表明,负载水平的大小对于碳纤维布的约束效果是有明显影响的。随着负载水平的提高,第2阶段刚度、峰值点应力和应变均逐渐下降;而碳纤维布包裹层数的增加,则放大了这种效应。 16 square-section concrete columns confined by CFRP sheet were tested in uniaxial compression involved in different preload ratio and CFRP plies.The failure characteristic and mechanics behavior of confined concrete columns were presented,and the descending of the peak stress and strain of confined concrete due to preload were analyzed.The experimental results indicated that the confinement effect of CFRP was influenced by preload ratio observably.The second stiffness,the peak stress and strain declined with preload ratio ascending,and the extent developed with the enhancement of CFRP ply.
出处 《四川大学学报(工程科学版)》 EI CAS CSCD 北大核心 2010年第6期56-60,共5页 Journal of Sichuan University (Engineering Science Edition)
基金 国家自然科学基金资助项目(50678150) 国家科技支撑计划课题资助项目(2009BAJ28B01) 西南交通大学校科学基金资助项目(2008A02 2008A05)
关键词 碳纤维布 混凝土方柱 负载水平 峰值点应力 峰值点应变 Carbon Fiber Reinforced Plastic(CFRP) sheet square-section concrete preload ratio preload ratio peak stress peak strain
  • 相关文献

参考文献4

二级参考文献25

  • 1曹双寅,敬登虎,孙宁.碳纤维布约束加固混凝土偏压柱的试验研究与分析[J].土木工程学报,2006,39(8):26-32. 被引量:36
  • 2天津大学 同济大学 等.混凝土结构[M].北京:中国建筑工业出版社,1997..
  • 3Karbhari V M, Gao Y Q. Composite jacketed concrete under uniaxial compression-verification of simple design equations[J]. Journal of Materials in Civil Engineering, 1997, 9(4) : 185-193.
  • 4Teng J G, et al. FRP strengthened RC Structures [M]. England: John Willey & Sons, Ltd, 2002.
  • 5Campione G, Miraglia N. Strength and strain capacities of concrete compression members reinforced with FRP [J]. Cement & Concrete Composites, 2003, 25: 31-41.
  • 6Mirmiran A, Shahawy M, Samaan M, et al. Effect of column parameters on FRP-confined concrete [J]. Journal of Composite for Construction, 1998, 2 (4): 175-185.
  • 7Rochette P, I.abossiere P. Axial testing of rectangular column model confined with composites [ J ]. Journal of Composites for Construction, 2000, 4 (3) : 129 - 136.
  • 8Toutanji H A. Stress-strain characteristics of concrete columns externally confined with advanced fiber composite sheets [J].ACI Materials Journal, 1999, 96 (3) : 397 - 404.
  • 9Wang Y C, Restrepo J I. Investigation of concentrically loaded reinforced concrete columns confined with glass fiber-reinforced polymer jackets [J]. ACI Structural Journal, 2001,98 (3) : 377 - 385.
  • 10Bazant Z P, Tsubaki T. Total strain theory and path-dependence of concrete [J]. Journal of the Engineering Mechanics Division, 1980, 106 (6): 1151-1173.