摘要 隧道拱顶下方最高温度是结构防火设计中的一个重要参数,对不同火灾工况下隧道拱顶附近最高温度的变化规律进行数值模拟研究。对比分析网格尺寸对火灾模拟结果的影响,结果显示当网格尺寸为0.1D*时模拟结果比较准确。分析了不同纵向通风风速、不同火源热释放速率及不同火源面到拱顶距离的情况下Kurioka最高温度模型的有效性,得出Kurioka最高温度模型在通风风速较小或不通风情况下是失效的。最后,对模型进行修正,给出一个具有广泛应用的隧道拱顶附近最高温度预测模型。 Because the maximum temperature below the tunnel vault is an important parameter of fire protection structure design,the numerical simulation study on maximum temperature law around the tunnel vault under different fire was carried out. The influence of grid size on the result of imitation was compared and analyzed,it shows that the result is more accurate when the grid size is 0.1 D*. Based on this,the validities of Kurioka maximum temperature were proved by analyzing longitudinal ventilate speeds,fire sources release speed and different stance between fire sources and vault,which shows that the Kurioka maximum temperature model is invalid under the situation of slow ventilation speed and no ventilation. In view of this,the model was revised and a widely-employed tunnel vault maximum temperature prediction model was provided.
出处 《中国安全科学学报》 CAS CSCD 北大核心 2010年第4期27-31,共5页 China Safety Science Journal
基金 铁道部科技研究开发计划项目(2006G007-C-1) 中南大学研究生教育创新工程项目(2009ssxt123)
关键词 火灾 铁路隧道 网格尺寸 最高温度 Kurioka预测模型 fire railway tunnel grid size maximum temperature Kurioka predict model
  • 相关文献

参考文献10

  • 1徐志胜,万俊,王薇.火灾下盾构隧道管片衬砌热力耦合数值分析[J].中国安全科学学报,2009,19(10):46-51. 被引量:9
  • 2李颖臻,雷波.隧道间联络通道临界风速模型[J].铁道学报,2008,30(3):87-90. 被引量:13
  • 3王彦富,蒋军成,龚延风,钟星灿,茅靳丰.隧道火灾拱顶附近烟气最高温度的研究[J].中国安全科学学报,2007,17(10):39-44. 被引量:23
  • 4郭春,王明年,赵海东.铁路特长隧道火灾应急救援问题研究[J].中国安全科学学报,2007,17(9):153-158. 被引量:24
  • 5R. L. Alpert.Calculation of response time of ceiling-mounted fire detectors[J]. Fire Technology . 1972 (3)
  • 6R.L.Alpert.Turbulent ceiling-jet induced by large-scale fires. Combustion Science and Technology . 1975
  • 7F. Vuilleumier,A. Weatherill,B. Crausaz.Safety aspects of railway and road tunnel: example of the Lotschberg railway tunnel and Mont-Blanc road tunnel. Tunnelling and Underground Space Technology . 2002
  • 8Hitoshi Kuriok,Yasushi Oka,Hiroomi Satoh,et al.Fireproperties in near field of square fire source with longitu-dinal ventilation in tunnels. Fire Safety Journal . 2003
  • 9Yasushi O,Atkinson G T.Control of smoke flow in tunnel fires. Fire Safety Journal . 1995
  • 10Wu Y,Bakar MZA.Control of smoke flow in tunnel fires using longitudinal ventilation systems-a study of the critical velocity. Fire Safety Journal . 2000

二级参考文献38

共引文献65

同被引文献143

引证文献14

二级引证文献58

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部