摘要
目的选择最适当的胰腺快速MR成像序列。材料与方法对20例胰腺正常者行六种快速MR成像序列检查,其中包括四种快速自旋回波序列(TSE—T1WI、T1FS、T2WI、T2FS)和二种梯度回波序列(GRE—TFE、FFE),然后对所得图像进行定量、定性分析。结果定量分析表明,T1FS有最高的胰腺信噪比。定性分析表明,T1WI显示脾静脉最好,且能同时清楚显示肠系膜上血管、门静脉和腹腔动脉。T1FS的伪影最少,且能同时清楚显示胰——十二指肠分界、胰一胃分界及肠系膜上静脉。T2WI的图像质量及对胰一十二指肠分界显示最好,且能同时清楚显示胆总管、肠系膜上血管、门静脉和腹腔动脉。T2FS显示胆总管最好,显示胰一十二指肠分界的能力同T2WI,同时能清楚显示门静脉。TFE和FFE无明显的优点。六个序列中任何一个,均不能使正常胰管成像。结论在正常胰腺快速MR成像序列中,T1FS和T2WI优于其它序列。
Purpose To Select the most suitable MRI sequence for pancreas. Materials and methods Six sequences including 4 fast spin echo sequences (TSE -T1 WI. T1 FS. T2 WI. T2 FS ) and 2 gradient echo sequences (GRE - TFE.FFE ) were used in 20 cases with normal pancreas. The images from these sequences were analysed quantitatively and qualitatively. Results Quantitative analysis showed that the T1FS had the highest pancreatic SNR. Qualitative analysis showed that the T1WI was the best sequence for demonstrating the splenic vein and could clearly show the superior mesenteric vessels .the portal vein and the coeliac artery. The T,FS had the least artifact and could clearly show the boundary between the pancreas and duodenum. the boundary between the pancreas and stomach as well as the superior mesenteric vein. The quality of images and the demonstration of the boundary between the pancreas and duodenum were the best in T,WI. The common binary duct.the superior mesenteric vessels .the portal vein and the coeliac artery could be clearly shown in the T2WI at the same time. The T2FS was the best sequence for demonstrating the common binary duct and it's ability to demonstrate the boundary between the pancreas and duodenum was the same as T2WI's. T2WI could also clearly show the portal vein. No obvious advantage was found in the TFE and FFE. None of the six sequences mentioned above could show the normal pancreatic duct. Conclusion The T1FS and T2WI were superior to other fast MRI sequences for normal pancreas.
出处
《医学影像学杂志》
1999年第2期76-79,共4页
Journal of Medical Imaging