摘要 磷光增感屏的内禀性质对磷光增感屏的成像性能影响很大.基于米氏(Mie)散射理论,计算得到磷光增感屏在不同颗粒尺寸和不同颗粒堆积密度情况下的散射系数和吸收系数.然后利用Monte Carlo(MC)方法模拟了可见光光子在磷光增感屏Gd2O2S:Tb(GOS)内的散射和吸收事件,得到磷光增感屏内不同位置处的可见光收集效率.利用MCNP程序模拟X射线束在磷光增感屏内的能量沉积分布,得到了金属-磷光增感屏总的点扩展函数(PSF).结果表明,在兆伏X射线成像系统中,使用小颗粒尺寸和高堆积密度的GOS磷光屏,可以改善增感屏系统的空间分辨率. Light absorption and scatteing coefficients of phosphor grain with different sizes and packing densities are computed with Mie theory.Optical photons in a granular phosphor screen are modeled by simulating scattering and absorption events of individual optical photons by Monte Carlo method(MC).Depth-dependent optical collection efficiencies are obtained.Using MCNP,distribution of energy deposition of 6 MeV mono-energetic X-ray in tungsten and phosphor screen is modeled.The point spread function of screen is given as a convolution of energy deposition kernel and optical kernel.Granular screens of smaller grain and higher packing density exhibit better spatial resolution in megavoltage radiography.
出处 《计算物理》 EI CSCD 北大核心 2010年第6期816-822,共7页 Chinese Journal of Computational Physics
基金 国家自然科学基金委员会与中国工程物理研究院联合基金(10576006) 中国工程物理研究院科学技术发展基金(编号2009B0202020和2007A01001)资助项目
关键词 粒状磷光屏 米氏理论 点扩展函数 空间分辨率 granular phosphor screens Mie theory point spread function resolution
  • 相关文献

参考文献2

二级参考文献14

  • 1王凌,徐之海,冯华君.多分散高浓度介质偏振光后向扩散散射的Monte Carlo仿真[J].物理学报,2005,54(6):2694-2698. 被引量:12
  • 2Quillin S. A Pixelated BGO Scintillator Array for High Energy ' Flash' Radiography[J]. IEEE Nucl. Sci. Syrup. Conf. Record, 2004, 2(16-22). 794-797.
  • 3Swank R K. Calculation of Modulation Transfer Functions of X-Ray Fluorescent Screens[J]. Appl.Opt. , 1973, 12(8): 1865-1870.
  • 4Barrett H H . Radiological Imaging: The Theory of Image Formation, Detection, and Processing [M]. New York: Academic Press, 1981.
  • 5Carrier C. Theoretical Modelling of Light Transport in Rectangular Parallelepipedic Scintillators [J]. Nucl. Instr. and Meth., 1990, A292(3): 685-692.
  • 6Gabriel T A. Lillie. Scintillation Light Transport and Detection[J]. Nucl. Instr. and Meth., 1987, A258:242-245.
  • 7Radcliffe T. Monte Carlo Optimization of Metal/ Phosphor Screens at Megavoltage Energies [J]. Med. Phys. ,1993, 20(4):1161-1169.
  • 8Badano A. Optical Blur and Collection Efficiency in Columnar Phosphors for X-ray imaging [J]. Nucl. Instr. and Meth., 2003, A508 :467-479.
  • 9Kausch C. Monte Carlo Simulations of the Imaging Performance of Metal Plate/Phosphor Screens Used in Radiotherapy[J]. Med. Phys. , 1999, 26(10) .2113-2124.
  • 10吴世法.近代成像技术与图像处理[M].北京:国防工业出版社,1997.139-145,200-207.

共引文献9

同被引文献11

  • 1刘进,章林文,刘军,施将君.密度提取中吸收系数的使用[J].强激光与粒子束,2007,19(2):293-296. 被引量:1
  • 2Radcliffe T, Barnea G, Shalev S, et al. Monte Carlo optimization of metal/phosphor screens at megavoltage energies[J]. Medical Physics, 1993, 20(4):1161-1169.
  • 3Quillin S, Aedy C. A pixelated BGO scintillator array for high energy flash radiography[J]. Nuclear Science Symposium Conference Re- cord, 2004, 2:794-797.
  • 4Sawant A. Theoretical analysis and experimental evaluation of a Cs(T1) based electronic portal imaging system[J]. Medical Physics, 2002, 29(6) : 1042-1051.
  • 5Kausch C, Schreiber B, Kreuder F, et al. Monte Carlo simulations of the imaging per{ormance of metal plate/phosphor screens used in ra- diotherapy[J]. Medical Physics, 1999, 26(10) : 2113-2124.
  • 6Bissonnette J P, Cunningham I A, Jaffray D A, et al. A quantum accounting and detective efficiency analysis for video-based portal imaging [J]. Medical Physics, 1997, 24(6) :815-826.
  • 7Swank R K. Absorption and noise in X-ray phosphors[J]. Journal of Applied Physics, 1973, 44(9):4199-4203.
  • 8X-5 Monte Carlo Team. MCNP-A general Monte Carlo N-particle transport code-version 5[R]. LA-UR-03-1987, 2003.
  • 9Schach yon Wittenau A E, Logan C M, Aufderheide M B, et al. Blurring artifacts in megavoltage radiography with a flat-panel imaging system: Comparison Monte Carlo simulations with measurements[J]. Medical Physics, 2002, 29( 11):2655-2665.
  • 10Cunningham I A, Westmore M S, Fenster A. A spatial frequency dependent quantum accounting diagram and detective quantum efficiency model of signal and noise propagation in cascaded imaging system s[J]. Medical Physics, 1994, 21(3):417-427.

引证文献2

二级引证文献2

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部