摘要 首先对600MW机组闭式循环冷却水泵(闭冷泵)变频改造实施过程进行了阐述,给出了改造过程中为保证系统可靠性所采取的措施;并对改造后的节能效果和安全可靠性进行了分析。因为此次技术改造实现了对闭式循环冷却水的压力PID闭环控制,除节电外,停止了对闭冷水再循环门的频繁操作,降低了闭冷水系统的压力,减轻了各冷却器调门的磨损,缓解了系统对管网密封性能的破坏,延长了设备的使用寿命,减小了维护量。最后提出了维护过程中应注意的一些要点。 The process of 600 MW unit closed circulating cooling water pumps frequency conversion retrofit was introduced,the measures for ensuring the system reliability and analyzed energy saving effect and safe reliable bene-fits after reformation were offered. Because this technical retrofit realized the PID close-loop control of closed circulating cooling water system,the frequency operation of recycle valve was avoided besides energy saving. And the pres-sure of the closed circulating cooling water system reduced,which would alleviate the valves’wear of coolers,ease the destroy of pipelines sealing performance,extend the service life of equipments and decrease the maintenance cost. At last some points for maintenance were given.
作者 何斌
出处 《电机与控制应用》 北大核心 2010年第11期50-55,共6页 Electric machines & control application
关键词 闭冷泵 变频调速 节能改造 closed circulating cooling water pumps variable frequency speed regulation energy saving retrofit
  • 相关文献

参考文献5

二级参考文献25

  • 1国建鸿,李振国,傅德平.大功率电力电子器件蒸发冷却技术研究[J].电力电子技术,2005,39(5):138-140. 被引量:9
  • 2张和平,杨忠民,胡伟,许贤昶.火电机组风机高压变频改造项目的节能预算与效果测试[J].电力设备,2006,7(5):13-15. 被引量:3
  • 3郭卉,宋福川,袁佳毅,李树柯.蒸发冷却电磁除铁器的研究[J].中国电机工程学报,2006,26(11):60-64. 被引量:9
  • 4郭涛,孙玉坤,任明炜,段大鹏.链式多电平变换器特定谐波消除脉宽调制方法研究[J].电力自动化设备,2006,26(12):52-54. 被引量:4
  • 5GU Guobiao. Calculation and experiment of hydro- generator stator bar with CLSC evaporative cooling syslem[C]//International Conference on Electrical Machines. Beijing. China : International Academic Publisbers, 1992:116- 121.
  • 6XIONG Nan,GU Guobiao. The development of the 400 MW evaporalion-cooling hydro-generator of LIJIAXIA power station [C]//Conference International Grands Reseaux Electriques. Paris, France : [ s.n. ]. 2000 : 1- 6.
  • 7LI Zhenguo ,GUO Jianhong,FU Deping. The applicalion and. research of the evaporative cooling techniology in the eletric and clectronic convertor equipment[C]// International Conference on Electrical Machines and Systems. Cheiudo. Kerea : [ s.n.] .2004: 256-258.
  • 8张燕宾.变频调速[M].北京:机械工业出版社,2007.
  • 9XIE Xiugang,X1ONG Nan. Research on the characteristics of base-plate heate transfer in applying evaporation cooling technology to power device[ C ] //International Conference on Electrical Machines and Systems. Chejudo,Korea: [s.n.],2004: 229 - 232.
  • 10BORDIGNON P,PAOLIN F. Water cooling system for high voltage thyristor valves[C]//IEEE-IAS Annual Meeting, Denver, Colorado, USA : IEEE, 1986 : 978- 983.