期刊文献+

大鼠眼球的高场磁共振成像研究 被引量:1

MRI of Rat Eyeballs
下载PDF
导出
摘要 该文旨在研究微型磁共振(MRI)对大鼠眼球的成像效果和应用.通过对10只SD大鼠的20只眼球进行7.0 T MRI检查,应用常规T1WI和T2WI序列高分辨率扫描;观察MRI图像上大鼠眼球的结构,并比较MRI测量与组织学显微镜下测量视网膜厚度结果.磁共振扫描清楚地显示了所有受试大鼠眼球的主要结构,包括角膜、晶状体、玻璃体、视网膜、巩膜、虹膜、睫状体、视神经.球壁结构磁共振图像层次与组织学结构层次有良好对应性;磁共振视网膜厚度测量值与显微镜下视网膜厚度测量数据进行配对t检验,P>0.05,二者无显著差异.由此得出的结论是小动物MRI可以对大鼠眼球细微解剖结构进行无创性的成像,为我们提供了一个研究大鼠眼科疾病模型的形态学及功能变化的手段. Twenty eyeballs from 10 rats were scanned at 7 T with T1-weighted imaging and T2-weighted imaging sequences.The structures of eyeballs on the images were evaluated,and the retinal thickness was measured on T2-weighted images.Most of the anatomical structures within the eyeballs could be distinguished on the images,including: cornea,lens crystalline,vitreous body,retina,sclera,iris and ciliary body,as well as the optic nerves.The thickness of retina determined with MRI was 209±20 μm,which was consistent with previous reports.There was no significant difference for the retinal thickness between MRI and the microscopic measurements.The findings from this study suggest that MRI can provide detailed anatomical imaging of rat eyeballs and optic nerve,and can be employed as a useful tool for investigating models of ophthalmological diseases.
出处 《波谱学杂志》 CAS CSCD 北大核心 2010年第4期630-634,共5页 Chinese Journal of Magnetic Resonance
基金 国家自然科学基金资助项目(30870704)
关键词 磁共振成像(MRI) 大鼠 眼球 视网膜 MRI rat eyeball retina
  • 相关文献

参考文献10

  • 1Berkowitz B A,Roberts R,Penn J S,et al.High-resolution manganese-enhanced MRI of experimental retinopathy of prematurity[J].Invest Ophthalmol Vis Sci,2007,48:4 733-4 740.
  • 2Berkowitz B A,Roberts R,Goebel D J,et al.Noninvasive and simultaneous imaging of layer-specific retinal functional adaptation by manganese-enhanced MRI[J].Invest Ophthalmol Vis Sci,2006,47:2 668-2 674.
  • 3Luan H,Roberts R,Sniegowski M,et al.Retinal thickness and subnormal retinal oxygenation response in experimental diabetic retinopathy[J].Invest Ophthalmol Vis Sci,2006,47:320-328.
  • 4Ito Y,Berkowitz B A.MR studies of retinal oxygenation[J].Vision Res,2001,41:1 307-1 311.
  • 5Cheng H,Nair G,Walker T A,et al.Structural and functional MRI reveals multiple retinal layers[J].Proc Natl Acad Sci USA,2006,103:17 525-17 530.
  • 6Berkowitz B A,Roberts R,Luan H,et al.Dynamic contrast-enhanced MRI measurements of passive permeability through blood retinal barrier in diabetic rats[J].Invest Ophthalmol Vis Sci,2004,45:2 391-2 398.
  • 7Shen Q,Cheng H Y,Pardue M T,et al.Magnetic resonance imaging of anatomical and vascular layers of the cat retina[J].J Magn Reson Imaging,2006,23:465-472.
  • 8Pop-Fanea L,Vallespin S N,Hutchison J M,et al.Evaluation of MRI for in vivo monitoring of retinal damage and detachment in experimental ocular inflammation[J].Magn Reson Med,2005,53:61-68.
  • 9Thuen M,Singstad T E,Pedersen T B,et al.Manganese-enhanced MRI of the optic visual pathway and optic nerve injury in adult rats[J].J Magn Reson Imaging,2005,22:492-500.
  • 10Watanabe T,Michaelis T,Frahm J.Mapping of retinal projections in the living rat using high-resolution 3D gradient-echo MRI with Mn^2+-induced contrast[J].Magn Reson Med,2001,46:424-429.

同被引文献10

  • 1张官萍,巫爱霞,戴朴,韩东一,陈俊生,韩正理,李永奇.中耳三维有限元模型的建立与中耳实体模型质量属性分析[J].中华耳鼻咽喉头颈外科杂志,2007,42(5):357-361. 被引量:6
  • 2Lewis JM, Obji M, Tano Y. A technique for contact lens fixation during vitreous surgery [ J ]. Ophthalmic Surg Lasers, 1996,27 (10) :891-893.
  • 3Cheng F, Fan KC. Linear diffraction grating interferometer with high alignment tolerance and high accuracy[ J]. Appl Opt,2011, 50 (22) :4550-4556.
  • 4吴建国,李筱荣,汪建涛,周小煦,苏龙,林松,等.用于显微镜下观察眼底和协助手术的动物角膜接触镜:中国,200920095713.5[P].2009-12-23.
  • 5Li N, Li XR, Yuan JQ. Effects of bone-marrow mesenchymal stem cells transplanted into vitreous cavity of rat injured by is- chemia/reperfusion[ J ]. Graefes Arch Clin Exp Ophthalmol, 2009,247(4) :503-514.
  • 6Oshima Y, Wakabayashi T, Sate) T, Ohji M, Tallo Y. A 27-gauge instnunent system for transconjunctival sutureless microincision vitrectomy surgery[J]. Ophthalmology,2010, 117( 1 ) :93-102.
  • 7Wu J, Zhou X, Sun G, Chen L, Li X, Hu Y, et al. Disposable sutureless silicone contact lens ring for use with a self-sealing can- nula system during vitrectomy [ J ]. Retina, 2010,30 ( 4 ) : 705- 707.
  • 8Wu J, Zhou X, Su L, Lin S, Sun G, Chen L, etal. A newly-designed positioning system for simultaneous indocyanine green and fluoreseein anterior segment angiography of the albino rab- bit[ J ]. Med Sci Monit,2010,16 ( 8 ) : 246-249.
  • 9兰晶,徐欣,姜广水,管延锦,黄海云,蓝菁.2种接连方式种植体的骨界面应力分析[J].华西口腔医学杂志,2008,26(4):443-447. 被引量:4
  • 10王丹,谢叻,裴国献,刘永刚,金丹,赵志球,姜晓锐.股骨转子间骨折三维虚拟手术研究[J].南方医科大学学报,2010,30(5):1165-1168. 被引量:9

引证文献1

二级引证文献1

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部