期刊文献+

某电厂循环水供水系统正常停泵过程的仿真研究 被引量:1

Simulation on the transition process of usual pump off for circulating water supply system in power plant
下载PDF
导出
摘要 针对某电厂循环水供水系统的特点,应用AFT ImpulseTM 4.0动态流体(水锤、汽锤)分析软件,对系统正常关机停泵水力过渡过程进行了计算机仿真,对泵出口阀不同两阶段关阀规律对应的过渡过程进行了比较分析,得出了较理想的关阀规律。根据仿真结果,正常关机同时停泵工况下,不当的关阀规律会导致水锤压力较大;而正常关机停1台泵或几台泵工况下,管道压力变化较小,泵反转比例是暂态过程中的控制点,较大的泵倒转比例容易损坏泵体。经计算机仿真计算得出的结论对提高电厂循环水系统的可靠性和运行稳定性具有一定意义。 In accordance with the characteristics of circulating water supply system in a power plant,a dynamic fluent(water hammer or air hammer) analysis software of AFT impulseTM 4.0 was applied for computer simulation of usual pump off in transition process.Comparing the transition process corresponded to different two-stage valve closing regulations,the optimized operations for closing valve were obtained.According to the simulation results,a wrong closing valve regulation could result in rising of water hammer pressure when all the pumps off usually.Under the conditions of one or more pumps stopping,the variation of pressure was small,and the pump reverse scale was the control point in transient process,higher pump reverse scale could destroy the pump easily.The conclusion had certain significance to improve reliability and stability of circulating water supply system in power plant.
出处 《供水技术》 2010年第6期17-20,共4页 Water Technology
关键词 循环水系统 水锤 仿真 停泵 circulating water system water hammer simulation pump stop
  • 相关文献

参考文献4

二级参考文献4

  • 1刘竹溪 刘光临.泵站水锤防护[M].北京:水利水电出版社,1998..
  • 2EB怀利 VL斯特里特 清华大学流体传动与控制教研组译.瞬变流[M].北京:水利电力出版社,1987..
  • 3刘光临.万家寨引黄入晋工程泵站水力过渡过程计算分析研究报告[C].武汉水利电力大学,1993-12..
  • 4蒋劲,李继珊,翁晓红,符向前.小浪底电站技术供水回水系统水锤防护研究[J].华中科技大学学报(自然科学版),2002,30(4):81-83. 被引量:11

共引文献10

同被引文献9

引证文献1

二级引证文献1

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部