期刊文献+

级联STATCOM直流侧电压平衡控制方法 被引量:27

Balancing control method of DC voltage of cascaded H-bridge STATCOM
下载PDF
导出
摘要 针对级联静止同步补偿器直流侧电容电压不平衡的问题,提出一种基于相移载波调制的直流侧电压平衡方法。该方法根据各个直流侧电压变化趋势来进行有选择的交换脉冲,将直流电压高于平均值且变高的模块的驱动信号与直流电压低于平均值且变低的模块的驱动信号交换,以载波相位差造成的直流侧不平衡来补偿开关损耗等造成的不平衡。该方法将直流侧平衡和静止同步补偿系统控制分开,算法简单,省略了直流侧辅助直流电源,使H桥模块更加简单,节省了成本。通过仿真分析和实验结果证实了该方法的正确性、有效性和实用性。 This paper presents a control strategy to balance the DC capacitor voltage for cascaded H-Bridge multilevel static synchronil compensator(STATCOM) based on phase-shifted carrier pulse width modulation.Choosing pulse transposition is adopted according to the trend of each DC voltage.Exchanging the driving signals of the module whose DC voltage is increasing and higher than the average with the driving signals of the module whose DC voltage is decreasing and lower than the average.The unbalance of the DC side caused by the switching loss and other losses could compensate the unbalance caused by the carrier phase shifted PWM.Control algorithm is simple since the balancing method separated the DC capacitor voltages balancing control from STATCOM control system.This new control method has the advantages of non-auxiliary DC power,simplifying H bridge module and lower cost.Simulation analysis and results prove its validity and utility.
出处 《电机与控制学报》 EI CSCD 北大核心 2010年第11期31-36,共6页 Electric Machines and Control
基金 黑龙江省青年基金(QC06C034)
关键词 相移载波 级联多电平 STATCOM 直流侧平衡 phase-shifted carrier pulse width modulation cascaded multilevel inverter static synchronic compensator voltage balancing control
  • 相关文献

参考文献12

  • 1HINGORANI N G, GYUGYI L. Uiwlerstanding FACTS: Concepts and Technology of Flexible AC Transmission Systems [ M ]. New York: IEEE press, 1999.
  • 2纪延超,刘庆国,骆济寿,杨以涵.新型无功补偿电源(ASVG)的仿真和实验[J].中国电机工程学报,1993,13(2):37-42. 被引量:4
  • 3SCftAUDER C, GERNHARDT M, STACEY E, et al. Development of a ± 100 MVAr static condenser for voltage control of transmission systems [ J ]. IEEE Transactions on Power Delivery, 1995, 10(3) : 1486 -1496.
  • 4HANSON D J, HORWILL C, GEMMELL B D, et al. A STAT- COM-based relocatable SVC project in the UK for national grid [ C ]//IEEE Power Engirveering Society Winter Meeting, January 27 -31,2002, New York, USA. 2002:532 -537.
  • 5沈斐,王娅岚,刘文华,梁旭,韩英铎.大容量STATCOM主电路结构的分析和比较[J].电力系统自动化,2003,27(8):59-65. 被引量:83
  • 6LAI J S, PENG F Z. Multilevel converters-a new breed of power converters[ J]. IEEE Transactious on Industry Application, 1996, 32(3) :509 -517.
  • 7RODRIGUEZ J, LAI J S, PENG F Z. Multilevel inverters : a survey of topologies, controls, and applications [ J ]. IEEE Transactions on Industry Application, 2002, 49(4) :724 -738.
  • 8耿俊成,刘文华,袁志昌.链式STATCOM电容电压不平衡现象研究(一)仿真和试验[J].电力系统自动化,2003,27(16):53-57. 被引量:91
  • 9耿俊成,刘文华,袁志昌.链式STATCOM电容电压不平衡现象研究(二)数学模型[J].电力系统自动化,2003,27(17):35-39. 被引量:71
  • 10PENG F Z, LAI J S. A multilevel voltage source inverter with separate DC sources for static var generation[ J ]. IEEE Transactions on Industry Application, 1996, 32 (5) : 1130 - 1138.

二级参考文献38

  • 1魏文辉,刘文华,宋强,袁志昌,倪镭,邹彬.基于逆系统方法有功—无功解耦PWM控制的链式STATCOM动态控制策略研究[J].中国电机工程学报,2005,25(3):23-28. 被引量:88
  • 2魏文辉,宋强,滕乐天,王伟,刘文华,袁志昌.基于反故障控制的链式STATCOM动态控制策略的研究[J].中国电机工程学报,2005,25(4):19-24. 被引量:31
  • 3刘文华,宋强,张东江,陈天锦,滕乐天,郑东润.50MVA静止同步补偿器链节的等价试验[J].中国电机工程学报,2006,26(12):73-78. 被引量:24
  • 4Meynard T A, Fadel M, Aouda N. Modeling of Multilevel Converters. IEEE Trans on Industrial Electronics, 1997, 44(3).
  • 5Peng F Z, Lai J S. Dynamic Performance and Control of a Static Var Generator Using Cascade Multilevel Inverters. IEEE Trans on Industry Applications. 1997, 33(3) : 748-755.
  • 6Woodhouse M L, Donoghue M W, Osborne M M. Type Testing of the GTO Valves for a Novel STATCOM Convertor. AC-DC Power Transmission. In: Seventh International Conference on AC-DC Power Transmission (IEE Conference Publication No485). London (UK): IEE, 2001. 84-90.
  • 7Sumi Y, Harumoto Y, Hasegawa T, et al. New Static VAR Control Using Force-commutated Inverters. IEEE Trans on Power Apparatus and Systems, 1981, 100(9): 4216-4224.
  • 8Edwards C W, Mattern K E, Stacey E J, et al. Advanced Static VAR Generator Employing GTO Thyristors. IEEE Trans on Power Delivery, 1988, 3(4) :1622-1627.
  • 9Mori S, Matsuno K, Hasgawa T, et al. Development of a Large Static VAR Generator Using Self-commutated Inverters for Improving Power System Stability. IEEE Trans on Power Systems, 1993, 8(1): 371-377.
  • 10Ichikawa F, Suzuki K, Nakajima T, et al. Development of Selfcommutated SVC for Power System. In: Power Conversion Conference Record. Yokohama: 1993. 609-614.

共引文献308