期刊文献+

火力发电厂管道支吊架检查与调整 被引量:3

Inspection and Adjustment of Steam and Water Pipe Support & Hanger in Thermal Power Plant
下载PDF
导出
摘要 火电厂汽水管道支吊架失效可造成管道损坏,影响机组的安全运行。介绍火电厂管道支吊架所承受的静、动荷载及偶然荷载,支吊架的一次应力、二次应力的校核方法及常见的支吊架限位受阻、吊架杆偏斜等破坏形式,并给出一些调整思路,便于指导工作中遇到的实际问题。 Steam and water pipe support hanger failure can cause the pipeline damage in thermal power plant,and also has passive influence on the safe operation of units.This article introduces the static-dynamic load and accidental load on pipe support hanger, check method for primary and secondary stress acted on the pipe support hanger as well as its typical failure mode,and thus to give the adjustment thinking so as to solve practical problems.
作者 左风光
出处 《陕西电力》 2010年第11期88-90,共3页 Shanxi Electric Power
关键词 火力发电厂 支吊架 应力校核 破坏形式 调整 thermal power plant support & hanger stress check failure mode adjustment
  • 相关文献

参考文献5

二级参考文献3

  • 1王军民,康豫军,等.陕西宝源热电有限责任公司3、4号机组主蒸汽管道支吊架状态检验、管系应力分析及调整[R].西安热工研究院有限公司,2005.
  • 2火力发电厂汽水管道应力计算技术规定.SDGJ6-90[S].北京:水利电力出版社,1991.
  • 3刘竹溪泵站水锤及其防护[M].

共引文献23

同被引文献7

引证文献3

二级引证文献6