期刊文献+

含水量对隧道衬砌混凝土耐火性能影响试验研究 被引量:3

Experimental research on influence for water content to the fire-resistant property of tunnel lining concrete
下载PDF
导出
摘要 火灾对特长公路隧道衬砌混凝土产生不同程度的损伤,含水量对隧道衬砌混凝土的耐火性能影响较大。对3种不同含水量的混凝土标准试块分别在不同的温度条件下(200,400,600,800,1 000℃)恒温加热5 h后静置冷却,测量其残余抗压强度和劈裂抗拉强度,并与常温下试块的强度进行比较。研究结果表明:高温下混凝土试块爆裂的频率和损伤程度随含水量的升高而加大,混凝土中水分加剧了混凝土耐火性能的劣化;C25混凝土发生爆裂的温度范围为500~600℃,爆裂的临界含水量为6%~8%。此结果可为火灾后隧道衬砌结构的鉴定、修复与补救提供参考。 Fire produces different degrees of damage to extra-long highway tunnel lining concrete,and the fire resistance performance of concrete is considerably effected by water content.Three groups of concrete standard test blocks with different water contents were heated for 5 hours at constant temperature respectively subjected to different temperature conditions(200,400,600,800,1 000 ℃) and put aside after being cooled.The residual compressive strength and splitting tensile strength was measured,compared with that of the test blocks at normal temperature.The results show that the blasting frequency and damage degree of concrete test blocks at high temperature increased with the rise of water content.The deterioration of fire resistance for concrete is exacerbated by the water in the concrete.The blasting temperature range and corresponding critical water content of C25 concrete is respectively 500~600 ℃ and 6%~8%.The research findings can provide reference for the identification,restoration and remediation of post-fire tunnel lining structure.
出处 《铁道科学与工程学报》 CAS CSCD 2010年第5期59-64,共6页 Journal of Railway Science and Engineering
基金 浙江省科技厅项目(2008C13041-2)
关键词 特长公路隧道 衬砌混凝土 含水量 高温 残余强度 extra-long highway tunnel lining concrete water content high temperature residual strength
  • 相关文献

参考文献7

二级参考文献54

共引文献145

同被引文献25

  • 1边松华,朋改非,赵章力,易全新.含湿量和纤维对高性能混凝土高温性能的影响[J].建筑材料学报,2005,8(3):321-327. 被引量:31
  • 2姚坚,朱合华,闫治国.隧道结构防火保护措施现状及评析[J].地下空间与工程学报,2007,3(4):732-736. 被引量:10
  • 3GB50016—2006建筑设计防火规范[S].北京:中国计划出版社,2006.
  • 4SANJ A YAN G, STOCKL J. Spalling of high-strength silica fume concrete in fire [J]. ACI Materials Journal, 1993,90(2):170-173.
  • 5G.H.A.van der Heijden, R.M.W.van Bijnen, L.Pel,H.P. Hui nink. Moisture transport in heated concrete, as studied by NMR, and its consequences for fire spalling [J]. Cement and Concrete Research,2007,37(6):894-901.
  • 6CHAN YN, PENG G F, ANSON M. Fire behavior of high- performance concrete made with silica fume at various moisture contents [J]. ACI Materials Journal, 1999,97(3):405-409.
  • 7CHAN S Y N , PENG G F, ANSON M. Fire Behavior ofHigh-performance Concrete Made with Silica Fume at Various Moisture Contents [ J ] ACI Materials Journal, 1999, 97 (3): 405-409.
  • 8KALIFA P, CHENE G, GALL E C. High-temperature Behavior of HPC With Polypropylene Fibers from Spalling to Micro-structure [ J] . Cement and Concrete Research, 2001, 31 (2): 87-99.
  • 9GAO Dan-ying, YAN Dong-ming, LI Xiang-yu. Splitting Strength of GGBFS Concrete Incorporating with Steel Fiber and Polypropylene Fiber After Exposure to Elevated Temp- eratures [J]. Fire Safety Journal, 2012, (54): 67 -73.
  • 10KAWASHIMA K, ZAFRA R, SASAKI T, et al. Effect of Polypropylene Fiber Reinforced Cement Composite and Steel Fiber Reinforced Concrete for Enhancing the Seismic Performance of Bridge Columns [ J ]Journal of Earthquake Engineering, 2011, 15 (8) : 1194 - 1211.

引证文献3

二级引证文献5

相关作者