摘要
目的为提高心电检测的准确度,在Windows95平台下建立了一个标准十二导心电信号同步检测分析系统。方法硬件上,采用多处理器的方法,实现十二导心电信号同步采集,以及采集和波形显示的并行操作。软件上,在时域和频域中,分析心电信号的各种不同参数及形态。结果该系统进行了临床检测和分析,满足了临床的要求。结论十二导心电信号的同步采集,以及时。
Objective To improve the
accuracy of ECG analysis,a system for detecting and analyzing the standard
12SynchronousLead ECG was set up on Windows 95. Method The system uses the method of
multiprocessor and realizes sampling the standard 12SynchronousLead ECG synchronously
and the parallel operation of synchronous acquisition and display of ECG.ECG signal was
analysed with all kinds of parameter and its pattern in time domain and in frequency domain.
Result Clinical test was well done and the result is satisfying. Conclusion In clinical diagnosis,
it is very important to sample the standard 12SynchronousLead ECG synchronously and to
analyze ECG simultaneously in time domain and in frequency domain.
出处
《航天医学与医学工程》
CAS
CSCD
1999年第3期204-208,共5页
Space Medicine & Medical Engineering
关键词
十二导同步
心电信号
频域分析
时域分析
Synchronouslead ECG
freguency domain analysis
time domain analysis