摘要
疾病预防控制机构废水具有重金属种类繁多、含病原体数量大、间断性排放等特点,通过运用混凝沉淀+曝气生物滤池(BIOFOR)+ClO2消毒工艺对其废水进行处理,处理后废水达到《医疗机构水污染物排放标准(》GB18466-2005)排放标准。
Usually,Waste water from CDC(Centers for Disease Control and Prevention)including various heavy metals,large quantity of pathogen,and the discharge is inconsistent.After the combination treatment of coagulation and sedimentation,BIOFOR,disinfection with ClO2,the waste water can achieve the "Medical establishment Water pollution Emissions Standard"(GB18466-2005).
出处
《环境科学与管理》
CAS
2010年第11期86-90,共5页
Environmental Science and Management
关键词
疾病预防控制中心
曝气生物滤池
废水处理
工程实例
centers for disease control and prevention(CDC)
biological aerated filters(BAF)
waste water treatment
project example