期刊文献+

水体中氨氮测定方法的比较——纳氏试剂光度法、靛酚蓝比色法 被引量:27

Comparison between Two N-ammoniacal Measurements in Water——Napierian Reagent Colorimetric Method and Indophenol-blue Colorimetric Method
下载PDF
导出
摘要 纳氏试剂光度法是氨氮的经典测定方法,但该方法的灵敏度不高。靛酚蓝比色法对氨氮具有特殊的敏感性和相关性,具有较高的准确度、精确度和敏感度。同时用两种方法对水样进行了测定,结果显示无显著性差异,但是靛酚蓝比色法较为方便,准确,易于操作,极大地减轻了分析人员的劳动强度,具有积极的现实意义。 Napierian Reagent Colorimetric Method is a classic method determining Ammonia Nitrogen.But sensitivity of the method is not high.Indophenol-blue Colorimetric Method has special sensitivity and correlation to ammonia nitrogen,and has high accuracy,precision and sensitivity.Samples are determined by two ways at the same time.Results show no significant differences.However,Indophenol-blue Colorimetric Method is more simple,accurate,and easier to operate.It greatly ease the analysis labors' intensity.So it has the positive significance.
出处 《环境科学与管理》 CAS 2010年第11期132-134,131,共4页 Environmental Science and Management
关键词 氨氮 纳氏试剂光度法 靛酚蓝比色法 比较 n-ammoniacal napierian reagent colorimetric method indophenol-blue colorimetric method comparison
  • 相关文献

参考文献1

  • 1国家环境保护局,水和废水监测方法(第四版)[M].北京:中国环境科学出版社,2002,49-246.

共引文献2

同被引文献351

引证文献27

二级引证文献122

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部