摘要
对一种变压器和电爆炸丝开关相结合的功率调节系统进行了研究。该系统能有效实现低阻抗的初级能源和高阻抗负载的匹配,为高阻抗负载提供高电压大功率的脉冲。给出了该系统在5kJ电容器能源组上的实验结果和数值模拟结果。在75Ω电阻负载上得到了脉宽为300ns、幅度大于600kV的高压脉冲。变压器耦合系数大于08。
The pulsed power conditioning system with transformer is studied.It contains a pulse transformer with a coupling efficiency of about 0 8,a fuse opening switch and a separating spark gap.Test results of the system are presented.When a 5kJ source is used to charge the system,the pulse,the peak voltage is 600kV and duration is 300ns,is obtained on a 75Ω resistance load.The numerical simulation results are presented.
出处
《爆炸与冲击》
EI
CAS
CSCD
北大核心
1999年第2期177-181,共5页
Explosion and Shock Waves