期刊文献+

可摘局部义齿不同加载条件下的三维有限元分析

Three-dimensional Finite Element Analysis of Three Removable Partial Dentures under Different Loading Conditions
下载PDF
导出
摘要 为分析对比3种可摘局部义齿修复重建肯氏I类缺失牙列的生物力学效果,对中国力学虚拟人数据库中现有模型进行改建,以此为基础形成三臂卡环固位、RPI卡环固位和种植体支持的RPI卡环固位3种不同方案的几何及有限元模型,导入ABAQUS6.5-1完成相应有限元分析,采用垂直载荷和斜向载荷,较好地模拟了口腔咀嚼过程.分析结果表明,RPI卡环固位义齿对抗垂直载荷与斜向载荷能力均优于三臂卡环固位义齿;有种植体支持的RPI卡环固位义齿对抗斜向载荷能力优于无种植体支持的RPI卡环固位义齿. To investigate the biomechanical effects of three removable partial dentures,the 3D finite element analysis(FEA) models of the mandible with molar missing,rehabilitated using traditional,RPI and implant-supported removable partial denture,were built based on models from the Mechanical Virtual Human of China database.The FEA was conducted in ABAQUS6.5-1.Two types of forces,vertical and oblique force,were loaded on these models.The FEA results suggest that the RPI removable partial denture is more helpful than the traditional RPD against the vertical and oblique loads,and the implant-supported RPD is more helpful than the other two,especially under oblique loading.
出处 《上海交通大学学报》 EI CAS CSCD 北大核心 2010年第11期1588-1594,共7页 Journal of Shanghai Jiaotong University
基金 国家自然科学基金资助项目(30530230)
关键词 肯氏I类缺失 可摘局部义齿 有限元方法 生物力学 distal-extension missing removable partial dentures finite element analysis biomechanics
  • 相关文献

参考文献4

二级参考文献18

  • 1李锦标,史书俊,刘雅琳,李长义,候晓明,张连云,高瑞亭.RPI及三臂卡环对游离端义齿支持组织应力分布的影响——三维光弹法观测[J].实用口腔医学杂志,1993,9(1):19-21. 被引量:3
  • 2Sato Y ,Tsuga K, Abe Y, et al. Dimensional measurement and finite element analysis of I - bar clasps in clinical use. J of Rehabil,2000,27(1): 935-939.
  • 3Demer WJ. An analysis of mesial rest I - bar clasp design. J Prosthetic Dent,1976,36(3) : 243 -253.
  • 4Krol AJ. Clasp design for extension base removable partial denture,J prosthetic Dent, 1973,29 ( 4 ) : 408 - 415.
  • 5Naik PR, Duncanson MG Jr, Mitchell DL, et al. Evaluation of stress and forces in selected I - bar using the finite element method. Journal of Prosthedont, 1997,6 ( 1 ) : 43 - 54.
  • 6Sato Y, Yuasa Y, Akagawa Y, et al. An investigation of preferable taper and thickness ratio for cast circumferential clasp arms using finite element analysis. Int J Prosthodont, 1995,8 (4) : 392 - 407.
  • 7Johnson DL, Strattion KJ, Duncanson MG. The effect of single plane curvature of half round cast clasps. J Dent Res, 1993,62:833 - 836.
  • 8Morris HF, Asgar K,Tilliton E. Stress relaxation testing, Part I New approach to the testing of removable partial denture alloy,wrought wires and clasp behavior. J Prosthetic Dent, 1981,46 (2): 133 - 141.
  • 9Sato Y, Yasuhiko A,Yuasa Y. Effect of friction coefficient on Akers clasp retention. J Prosthe Dent, 1997,78: 22 -7.
  • 10Morris HF, Asgar K. Physical properties and microstructure of four new commercial partial denture alloy. J Prosthe Dent, 1975,33:36 - 41.

共引文献21

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部