摘要 设计了由压电陶瓷施压的柔性变焦镜的结构。根据弹性力学建立了相应的数学模型,采用有限元法计算了镜面受力的挠变形值。当柔性变焦镜最大挠度为9μm时,镜面的曲率半径从610mm变至590mm,此时采用环形筋条结构的反射镜镜面和理想球面的面形偏差PV值仅为1μm,面形相对偏差为0.3%。 A new style of flexible focus variable mirror which is forced by piezoelectric ceramic is designed in this paper. Finite elements method is used to calculate the mirrors deflection and the deviation of surface shape is quoted to evaluate the mirrors imaging quality. When the maximum deflection is 9μm, the radius of mirrors curvature is varying from 610mm to 590mm and the PV value of deviation is 1μm, the relative deviation of surface shape is 0.3%.