期刊文献+

电子信息系统机房的磁场干扰环境

Environment of Disturbance from Magnetic Field to Electronic Information System Room
下载PDF
导出
摘要 对国家标准《电子信息系统机房设计规范》(GB 50174-2008)有关电子信息系统机房的磁场干扰环境所规定的要求提出质疑。笔者认为,基于磁场的类型和作用时间的长短,设备的抗扰度,实例和试验,文献记载等几点事实,该规范中对磁场干扰强度规定为不大于800 A/m是不合适的,并提出了自己的意见。 Some query about requirement of environment of disturbance from magnetic field in electronic information system room which is coded to state standard (GB 50174 - 2008) Code for design of electronic information system room. is introduced, based on following factors: kind of magnetic field and action time; immunity of equipment; example and experiment; record from literature. It is not suitable to coded magnetic field strength of disturbance to be less than 800 A/m.
作者 徐义亨
出处 《石油化工自动化》 CAS 2010年第6期18-19,27,共3页 Automation in Petro-chemical Industry
关键词 电子信息系统 机房 磁场强度 electronic information system computer room magnetic field strength
  • 相关文献

参考文献3

  • 1中华人民共和国质量监督检验检疫总局,中国国家标准化管理委员会.GB5017-2008电子信息系统机房设计规范[S].北京:中国标准出版社,2008.
  • 2中华人民共和国质量监督检验检疫总局,中国国家标准化管理委员会.GB/T17626.8-2006电磁兼容试验和测量技术工频磁场抗扰度试验[S].北京:中国标准出版社,2006.
  • 3中华人民共和国质量监督检验检疫总局,中国国家标准化管理委员会.GB/T17626.9-1998电磁兼容试验和测量技术脉冲磁场抗扰度试验[S].北京:中国标准出版社,1998.