摘要
采用扰动功率法对电压骤升、电压骤降、短时停电等短期电能质量扰动进行扰动源的判定,对公共连接点的各个支路,其扰动功率初始峰值极性作为扰动方向判定的依据,极性不同的支路为扰动源所在的支路。仿真结果表明,该方法对判定电压骤升、电压骤降、短时停电等短期电能质量扰动的扰动源有较好的效果。
The determination of short-term power quality disturbance source is put forward by disturbance power method in this paper.Polarity of the initial peak of disturbance power is the basis for disturbance direction.Disturbance source is located in the slip road which polarity is different.The result of simulation indicates that it is useful to recognize Disturbance source of voltage swell,voltage sag and voltage interruption with this method.
出处
《南方电网技术》
2010年第5期79-81,共3页
Southern Power System Technology
关键词
短期扰动
扰动功率
扰动源
short-term disturbance
disturbance power
disturbance source