为了解决非专业人群寻找穴位难、不准确、不易操作等难题,设计了一种以SPCE061A为核心MCU(Micro Control Unit)的简易人体穴位识别治疗仪。给出了系统结构和实现流程,提出了一种基于层次分析原理的新型穴位检测方法,并讨论了环境因素对穴位识别结果的影响。通过人体穴位检测实验表明,本系统的穴位与非穴位正确识别率可分别达到95%和98%以上,且输出频率可调、波形可变的脉冲电压可达到模拟中医针灸治疗的作用。与传统找穴位方法相比,该方案具有操作简单、功耗低、性价比高等优点。
To resolve the problem of distinguishing acupuncture point for the unprofessional persons,we design a recognition and detection instrument with SPCE061A.The principles and diagrams of hardware and software architecture of the entire system are described.Based on theories of skin resistances on the acupoint resistance,a new acupoint detect instrument containing electrical stimulating is invented.The recognition acuracy on acupuncture and non-acupuncture can reach to 95% and 98%,respectively.Controlled through a MCU(Micro Control Unit),the apparatus can output biphasic constant current and special pulses for electrical stimulation.The theory of meridians is significant for the basic theory of traditional Chinese medicine.The effects of environment on acupoint detection is discussed.Compared with the traditional method,this can improve and simplyfy the operation.
出处
《吉林大学学报(信息科学版)》
CAS
2010年第6期609-615,共7页
Journal of Jilin University(Information Science Edition)
基金
国家大学生创新实验计划基金资助项目(200905206)
关键词
穴位识别
穴位治疗
层次分析法
SPCE061A芯片
微处理器
acupoint detector
acupoint treatment
analytic hierarchy process
SPCE061A chip
micro control unit(MCU)